![Fimap GAMMA 66 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/fimap/gamma-66/gamma-66_use-and-maintenance-manual_2288977023.webp)
23
TROUBLE SHOOTING GUIDE
INSUFFICIENT WATER TO THE BRUSHES
-
Check that the cock is open (signal lamp on)
-
Check that there is water in the solution tank
MACHINE DOES NOT CLEAN WELL
-
Check thc condition of the brushes and rep lace if necessary (brushes must be
replaced when br istles arc 15 mm. high)
-
Check that brush prcssure is sufficient. Inercase as necessary using lever (1)
-
Use another type of brush rather than the standard brush. We recommend. to clean
floors with exceptionally difficu lt dirt, the use of special brushes that are supplied on
request and according to your specific needs (see "BRUSH SELECTION AND USE"
below)
SQUEEGEE DOES NOT DRY PERFECTLY
-
Check that the squeegee is clean
-
Check all adjustments (see "PREPARING THE MACHINE")
-
Clean the entire aspiration unit (see "DAILY MAINTENANCE")
-
Replace worn rubbers