background image

6

Combi drum 35 (pump)

1.  What's included

• 

PP basin

• 

PP drum with brushes

• 

70 micron stainless steel panel

• 

PP duct

• 

Water level meter with 3 pins

• 

Drum motor

• 

Submersible pump

• 

Spray tube with 4 sprayers (the first of which has a higher 
flow)

• 

2x 63 mm inlets

• 

3x 110 mm outlets

• 

3x 110 mm drum bypasses

• 

2x 1 1/2" drain with ball valve

• 

Control box

• 

Cover with safety lock

• 

100 L Bio wheels

2. Product description

The drum filter consists of a PP basin containing a PP drum with 
mesh.  The  drum  is  pump-fed  and  installed  beside  the  pond. 
The inlets are below the water surface level, and the dirty water 
is pump-fed through the floor drains or skimmers into the first 
filtration chamber. On the outflow side, the water flows through 
a slotted plate into the moving bed. Because the dirty water 
flows through the drum, contaminants in the water cling to the 
interior of the drum. As a result, less water can flow through the 
mesh and the water level on the inside of the drum rises. The 
water level meter detects this and initiates the flush cycle. This 
cycle consists of activating the drum motor and spray pump. 
This causes the drum to turn slightly more than one full rotation 
and  the  sprayers  flush  the  mesh  clean.  The  flush  water  then 
flows into the sewage along with the waste. The cycle repeats 
as often as necessary. 

3. Assembling the filter

The  housing  of  the  filter  consists  of  a  PP  basin  with  one 
partition. The partition is fitted with a silicone sealing strip at 
the  flange  which  separates  dirty  water  from  clean.  There  are 
also 3 holes in the partition which are covered with a cap. In 
case  of  a  breakdown  in  the  drum  control,  the  covers  can  be 
removed to enable the water to bypass the drum and flow past 
it  without  being  filtered.  This  enables  you  to  still  use  the 
biological filtration segment.

The basin is fitted with a removable waste drain. This can be 
removed  from  the  interior  of  the  drum,  which  saves  you  the 
trouble of having to disassemble the drainage line. The inclined 
surface  accelerates  the  water  flow,  causing  the  waste  to  be 
carried  along  with  it  into  the  drain.  There  are  also  4  brushes 
installed  on  the  inside  of  the  drum  which  sweep  away  any 
algae or other coarse particles that cling to the drain. The drum 
filter is fitted with a removable spray tube made of PP, which 
is equipped with flat jet nozzles. The sprayers feature a quick-
release system, making them easy to remove for cleaning. The 
water level meter in the basin consists of 3 electrodes, 1 flush 
level, 2 high-level safeties and 1 common electrode. The water 
level for initiating the flush cycle is adjustable. Inside the basin 
is a high-pressure submersible pump which supplies water to 
the sprayers under high pressure during the flush cycle. 

The drum motor is installed in a water-proof compartment inside 
the  biological  filtration  section.  The  shaft  is  enclosed  by  a 
retaining  ring  in  the  installation  plate.  The  shaft  connects  to 
the drum via a flange with a pipe. To remove the drum, you can 
simply detach this pipe-shaft connection, after which the drum 
can be taken out. You do not have to disassemble the motor to 
do this. The screens can be removed by detaching the tension 
straps and unscrewing the cover panel to remove it.

4. Instructions for use

The  Filtreco  combi  drum  filter  and  all  parts  and  accessories 
that it comes with may only be used as follows:

• 

for cleaning garden ponds

• 

according to the user manual and technical specifications 

• 

only with water temperatures b4 ˚C and +35 ˚C. 

• 

only suitable for transporting water

• 

not for commercial or industrial purposes

• 

not suitable for salt water

• 

never use without running water

• 

never  use  in  combination  with  chemicals,  foods  or 
flammable/explosive liquids

Содержание Drum 35

Страница 1: ...1 www filtreco nl It is clear www filtreco nl 100331 User manual Combi drum 35 pump EN Order number ...

Страница 2: ......

Страница 3: ...n only the best quality will do choose Filtreco High quality technology means quality of life for your koi It is clear Introduction This is the user manual for the Combi drum 35 pump By purchasing this Filtreco filter you have made an excellent choice Please read this user manual carefully before you start using this system This will enable you to familiarise yourself with the system first Any wor...

Страница 4: ......

Страница 5: ...allations 07 5 4 Safe use 07 6 Placement and setup 08 6 1 Connecting the control box 08 6 2 Connecting the electrodes and water level meter 08 7 First use 09 7 1 Sequence for first use 09 7 2 Adjusting water level meter 09 7 3 Flush cycle 09 8 Control box 10 9 Control panel malfunctions 10 10 Cleaning and maintenance 1 2 11 Troubleshooting 1 3 12 Winterising 1 3 13 Wear parts 1 3 14 Technical spec...

Страница 6: ...still use the biological filtration segment The basin is fitted with a removable waste drain This can be removed from the interior of the drum which saves you the trouble of having to disassemble the drainage line The inclined surface accelerates the water flow causing the waste to be carried along with it into the drain There are also 4 brushes installed on the inside of the drum which sweep away...

Страница 7: ... For your own safety always consult a professional electrician in case of any problems This system can only be connected to a power supply that matches its electrical specifications All specifications for this system can be found in this user manual The system must be protected by a residual current device with a fixed residual current of max 30 mA Use only extension cables and power dividers that...

Страница 8: ... adequate incline It is recommended to install a pipe with a flexible rubber sleeve These can compensate for small differences in dimensions and also absorb vibration They can also be detached to remove the drainage duct Always use high quality pipes with an adequate wall thickness Ideally use 45 degree elbow connectors Lay the pipes at a downward angle so that they can be fully emptied during the...

Страница 9: ...plug for the spray pump goes into the power socket labelled spray pump The plug for the drum motor goes into the power socket labelled drum motor The plug for the water pump s goes into the power socket labelled pond pump Any additional components connect into the power socket labelled spare Please make sure that the power sockets can support a total output of 2500 W from pond pump and spare combi...

Страница 10: ...p the flush cycle This button can be used either in manual or in automatic mode 2 Reset Error Resetting an error outage If the error is actually resolved it is possible for the system to work normally again If the error is reset but still continues to exist the Error LED will immediately light up again 3 Change Mode By pushing this button you can switch back and forth between Auto matic and Manual...

Страница 11: ...nd check whether the water level has reached the required operating level again Repeat the steps above if necessary If this continues to happen you must decrease the inflow capacity to the filter or increase the outflow capacity from the filter Door Error The cover contact is not closed The cover is not installed or is not closed properly The water pumps are switched off No flush cycle is possible...

Страница 12: ...ange Mode Your choice is now saved In manual mode you can change this again if you wish 10 Safety Switch If the Safety Doorswitch E is switched on the system is supplied with electrical current After you use Safety Doorswitch E the system will always start in Manual mode If you want to open the control box you must switch off Safety Doorswitch E or else the door cannot be opened This is an additio...

Страница 13: ...e the drum check the seal between the partition and the flange of the drum The high pressure pump does not work The plug is not plugged into the right power socket spray pump 12 Winterising To ensure proper functioning of the system do not allow the water temperature to decrease below 4 degrees Celsius Measures that you can take Place a cover or lid over the drain The control and motor cannot with...

Страница 14: ...14 Combi drum 35 pump 16 Technical diagram ...

Страница 15: ...15 www filtreco nl 17 Diagram for assembly in a pond P ...

Страница 16: ...16 Filtreco Nusterweg 69 NL 6136 KT Sittard The Netherlands CoC 14052952 VAT NL 58 28 235 B01 31 46 457 25 55 info filtreco nl www filtreco nl Filtreco is a WTH B V brand ...