background image

13

www.filtreco.nl

• 

Complete cleaning:

 

-  Switch off the "Main switch" and unplug the system from  

 

  the mains power supply.

 

-  Close  the  inlet  and  outlet  spouts  and  drain  the  water  

 

  through the valve until the filter is empty.

 

-  Remove the drain and clean it thoroughly.

 

-  Remove  the  drum  and  brushes  and  clean  them  

 

  under running water.

 

-  Remove the spray pump and clean it thoroughly.

 

-  Clean the entire inside of the filter.

• 

disassemble the drum as follows:

 

-  Disassemble  the  spray  tube  by  unscrewing  the 

 

  connector and removing the drain from the tube clamp.

 

-  Disassemble  the  drain  by  loosening  the  bolts. 

 

  Be careful not to lose the gasket and gasket rings!

 

-  Turn the drum until the bolt from the shaft connection  

 

  is on top. Remove this bolt.

 

-  Slide  the  drum  slightly  towards  the  partition  until  the  

 

  tube  is  separated  from  the  shaft  and  then  carefully  lift  

 

  the drum at an angle upwards out of the silicone seal. Lift  

 

  the drum out of the filter basin. Carefully set the drum  

 

  down to prevent damage to the screen.

• 

Assemble the drum as follows:

 

-  Carefully  lower  the  drum  into  the  filter  and  

 

  set its flange on the shafts of the partition.

 

-  Press  the  silicone  seal  into  the  flange  of  the  drum  on 

 

  all sides, using your hand.

 

-  Slide the drum with the flange side over the shaft.

 

-  Turn the drum around the shaft until the hole in the shaft 

 

  is positioned underneath the hole in the tube. Reinsert  

 

  the M8 x 15 bolt and screw it tightly.

11.  Troubleshooting

Error codes related to the Error LED are found in chapter 9. The 
following issues may occur:

• 

No water flow: 

 

-  Check whether the (slide) valves are open.

  

-  Check whether the water pumps are connected.

  

-  Check whether the inlet or outlet is clogged.

• 

Insufficient water flow: 

 

-  Check whether the inlet or outlet is clogged.

 

-  There are not enough inlet connections installed.

 

-  The circulation pump does not have enough capacity. 

 

-  There is dirty water and particles in the clean water side  

 

  outside the drum: check the seal between the partition  

 

  and the flange of the drum.

• 

The high-pressure pump does not work:

 

-  The plug is not plugged into the right power socket (spray  

 

  pump).

12.  Winterising

To ensure proper functioning of the system, do not allow the 
water temperature to decrease below +4 degrees Celsius.

Measures that you can take:

• 

Place a cover or lid over the drain.

• 

The  control  and  motor  cannot  withstand  freezing 
temperatures. Be sure to place them in a location that is 
protected from rain and frost.

In case water temperatures drop below +4 degrees Celsius or 
there is a chance of freezing, discontinue using the system.

• 

Drain the system and clean it according to the instructions

• 

Allow the surrounding pipes to drain

• 

Leave the valves open

• 

Protect  the  pipes  and  other  components  from  frost  if 
necessary.

13.  Wear parts

The following parts may be subject to wear:

• 

Silicone drum seal 

Order number  

100754

• 

Retaining ring 

Order number  

100757

• 

Brush 

Order number 

100758 

• 

Drum screens 

Order number  

100701

14.  Technical specifications

• 

Operating voltage: 

Vac 230V 

• 

Plug: 

16 A Euro plug

• 

Total power output: 

3680 Watts

• 

Cable length: 

3 m

• 

Drum diameter: 

40 cm

• 

Drum length:  

40 cm

• 

Max. flow:  

35 m

3

/h

• 

Weight:  

100 kg

• 

Height above water level: 

completely

• 

Min. water level:  

As stated

• 

Max. water level: 

As stated 

• 

Number of panels: 

2

• 

Number of sprayers: 

4

15.  Wiring and power outages

If the control box is further away than the 3-metre cable length, 
use  a  CE-approved  splash-resistant  extension  cable  to  reach 
the motor and the spray pump.

The cables for the water level meter cannot be extended using 
a  power  cable.  This  may  cause  the  system  to  malfunction. 
Original Filtreco cables can be ordered separately. Any damage 
to  the  control  box  caused  by  your  own  wiring  or  third-party 
extension cables is not covered by warranty. 

If following a power outage, the power circuit it reactivated, the 
control box will revert to its previous mode (the mode which 
was activated for longer than 10 seconds): automatic mode in 
automatic  mode  and  manual  mode  in  manual  mode.  The 
previously selected flush time will also be reactivated. 

Содержание Drum 35

Страница 1: ...1 www filtreco nl It is clear www filtreco nl 100331 User manual Combi drum 35 pump EN Order number ...

Страница 2: ......

Страница 3: ...n only the best quality will do choose Filtreco High quality technology means quality of life for your koi It is clear Introduction This is the user manual for the Combi drum 35 pump By purchasing this Filtreco filter you have made an excellent choice Please read this user manual carefully before you start using this system This will enable you to familiarise yourself with the system first Any wor...

Страница 4: ......

Страница 5: ...allations 07 5 4 Safe use 07 6 Placement and setup 08 6 1 Connecting the control box 08 6 2 Connecting the electrodes and water level meter 08 7 First use 09 7 1 Sequence for first use 09 7 2 Adjusting water level meter 09 7 3 Flush cycle 09 8 Control box 10 9 Control panel malfunctions 10 10 Cleaning and maintenance 1 2 11 Troubleshooting 1 3 12 Winterising 1 3 13 Wear parts 1 3 14 Technical spec...

Страница 6: ...still use the biological filtration segment The basin is fitted with a removable waste drain This can be removed from the interior of the drum which saves you the trouble of having to disassemble the drainage line The inclined surface accelerates the water flow causing the waste to be carried along with it into the drain There are also 4 brushes installed on the inside of the drum which sweep away...

Страница 7: ... For your own safety always consult a professional electrician in case of any problems This system can only be connected to a power supply that matches its electrical specifications All specifications for this system can be found in this user manual The system must be protected by a residual current device with a fixed residual current of max 30 mA Use only extension cables and power dividers that...

Страница 8: ... adequate incline It is recommended to install a pipe with a flexible rubber sleeve These can compensate for small differences in dimensions and also absorb vibration They can also be detached to remove the drainage duct Always use high quality pipes with an adequate wall thickness Ideally use 45 degree elbow connectors Lay the pipes at a downward angle so that they can be fully emptied during the...

Страница 9: ...plug for the spray pump goes into the power socket labelled spray pump The plug for the drum motor goes into the power socket labelled drum motor The plug for the water pump s goes into the power socket labelled pond pump Any additional components connect into the power socket labelled spare Please make sure that the power sockets can support a total output of 2500 W from pond pump and spare combi...

Страница 10: ...p the flush cycle This button can be used either in manual or in automatic mode 2 Reset Error Resetting an error outage If the error is actually resolved it is possible for the system to work normally again If the error is reset but still continues to exist the Error LED will immediately light up again 3 Change Mode By pushing this button you can switch back and forth between Auto matic and Manual...

Страница 11: ...nd check whether the water level has reached the required operating level again Repeat the steps above if necessary If this continues to happen you must decrease the inflow capacity to the filter or increase the outflow capacity from the filter Door Error The cover contact is not closed The cover is not installed or is not closed properly The water pumps are switched off No flush cycle is possible...

Страница 12: ...ange Mode Your choice is now saved In manual mode you can change this again if you wish 10 Safety Switch If the Safety Doorswitch E is switched on the system is supplied with electrical current After you use Safety Doorswitch E the system will always start in Manual mode If you want to open the control box you must switch off Safety Doorswitch E or else the door cannot be opened This is an additio...

Страница 13: ...e the drum check the seal between the partition and the flange of the drum The high pressure pump does not work The plug is not plugged into the right power socket spray pump 12 Winterising To ensure proper functioning of the system do not allow the water temperature to decrease below 4 degrees Celsius Measures that you can take Place a cover or lid over the drain The control and motor cannot with...

Страница 14: ...14 Combi drum 35 pump 16 Technical diagram ...

Страница 15: ...15 www filtreco nl 17 Diagram for assembly in a pond P ...

Страница 16: ...16 Filtreco Nusterweg 69 NL 6136 KT Sittard The Netherlands CoC 14052952 VAT NL 58 28 235 B01 31 46 457 25 55 info filtreco nl www filtreco nl Filtreco is a WTH B V brand ...

Отзывы: