6 Error LEd:

This LED glows red whenever an error or outage occurs. This 
may indicate any of the following errors:

System Error:

Error  in  the  control  box  (relay,  electrodes,  automation, 
motherboard).

 

-  The water pumps are switched off. 

 

-  No flush cycle is possible.

• 

The Main Switch is switched off

• 

Pull all the plugs out of the box

• 

Unplug the system's power supply cable

• 

Switch the F1 automat off and then on again

• 

Close the box and reconnect it to power

• 

Switch the Main Switch on again

• 

If the error continues, contact Filtreco

Level Error:

The water level in the filter has become too high. More water is 
being pumped into the filter than is flowing out of it.

 

-  The water pumps are switched off. 

 

-  No flush cycle is possible.

• 

Remove the cover and look for what's causing the problem.

• 

Check the inlet and outlet lines.

• 

If the outer end of the high-level electrode is above water 
again:

 

-  place the cover on the filter

 

-  press "Reset Error" 

 

-  The mode will then switch to Manual

• 

Press "Start" to initiate the manual flush cycle.

 

-  The "Flush" LED turns green

 

-  Check to make sure the spray pump and motor are working

 

-  If  the  motor  is  not  working,  check  whether  its  plug  is  

 

  connected

 

-  If the spray pump is not working, check whether its plug 

 

  is connected

 

-  When  the  flush  cycle  is  complete,  the  "Flush"  LED 

 

  switches off again.

 

-  Remove  the  cover  and  check  whether  the  water  level  

 

  has reached the required operating level again

 

-  Repeat the steps above if necessary

 

-  If this continues to happen, you must decrease the inflow  

 

  capacity  to  the  filter  or  increase  the  outflow  capacity  

 

  from the filter.

Door Error:

The cover (contact) is not closed. The cover is not installed or 
is not closed properly.

 

-  The water pumps are switched off. 

 

-  No flush cycle is possible.

• 

Check whether the cover is closed properly

• 

Press "Reset Error" to return to the manual cycle

• 

The  "Door"  LED  switches  off  and  the  "Manual"  LED 
switches on

• 

Press "Change Mode" to return to automatic mode.

If the error continues, check whether the magnet is still in place 
under the holder for the cover. If so, then perform the following 
steps:

• 

Switch off the "Main Switch" 

• 

Disconnect the power plug from the mains

• 

Open the box

• 

Check  whether  the  DR+  and  DR-  cables  are  properly 
connected

Interval Error:

This occurs when 50 flush cycles have occurred in a row with 
a pause of less than 3 minutes between each cycle. This may 
occur when the water is heavily contaminated.

 

-  The water pumps are switched off.

• 

Set the flush-cycle electrode to the highest level. Now, a 
flush cycle will be initiated later.

• 

Check the outflow lines to see whether they are clogged.

• 

Check the sprayer heads and clean them if needed.

If this does not help, reduce the incoming flow until the most 
heavy contamination is eliminated.

7 Auto mode LEd:

The LED glows then the system is in automatic mode.

8 manual mode LEd: 

The LED glows when the system is in manual mode.

Содержание Drum 35

Страница 1: ...1 www filtreco nl It is clear www filtreco nl 100331 User manual Combi drum 35 pump EN Order number ...

Страница 2: ......

Страница 3: ...n only the best quality will do choose Filtreco High quality technology means quality of life for your koi It is clear Introduction This is the user manual for the Combi drum 35 pump By purchasing this Filtreco filter you have made an excellent choice Please read this user manual carefully before you start using this system This will enable you to familiarise yourself with the system first Any wor...

Страница 4: ......

Страница 5: ...allations 07 5 4 Safe use 07 6 Placement and setup 08 6 1 Connecting the control box 08 6 2 Connecting the electrodes and water level meter 08 7 First use 09 7 1 Sequence for first use 09 7 2 Adjusting water level meter 09 7 3 Flush cycle 09 8 Control box 10 9 Control panel malfunctions 10 10 Cleaning and maintenance 1 2 11 Troubleshooting 1 3 12 Winterising 1 3 13 Wear parts 1 3 14 Technical spec...

Страница 6: ...still use the biological filtration segment The basin is fitted with a removable waste drain This can be removed from the interior of the drum which saves you the trouble of having to disassemble the drainage line The inclined surface accelerates the water flow causing the waste to be carried along with it into the drain There are also 4 brushes installed on the inside of the drum which sweep away...

Страница 7: ... For your own safety always consult a professional electrician in case of any problems This system can only be connected to a power supply that matches its electrical specifications All specifications for this system can be found in this user manual The system must be protected by a residual current device with a fixed residual current of max 30 mA Use only extension cables and power dividers that...

Страница 8: ... adequate incline It is recommended to install a pipe with a flexible rubber sleeve These can compensate for small differences in dimensions and also absorb vibration They can also be detached to remove the drainage duct Always use high quality pipes with an adequate wall thickness Ideally use 45 degree elbow connectors Lay the pipes at a downward angle so that they can be fully emptied during the...

Страница 9: ...plug for the spray pump goes into the power socket labelled spray pump The plug for the drum motor goes into the power socket labelled drum motor The plug for the water pump s goes into the power socket labelled pond pump Any additional components connect into the power socket labelled spare Please make sure that the power sockets can support a total output of 2500 W from pond pump and spare combi...

Страница 10: ...p the flush cycle This button can be used either in manual or in automatic mode 2 Reset Error Resetting an error outage If the error is actually resolved it is possible for the system to work normally again If the error is reset but still continues to exist the Error LED will immediately light up again 3 Change Mode By pushing this button you can switch back and forth between Auto matic and Manual...

Страница 11: ...nd check whether the water level has reached the required operating level again Repeat the steps above if necessary If this continues to happen you must decrease the inflow capacity to the filter or increase the outflow capacity from the filter Door Error The cover contact is not closed The cover is not installed or is not closed properly The water pumps are switched off No flush cycle is possible...

Страница 12: ...ange Mode Your choice is now saved In manual mode you can change this again if you wish 10 Safety Switch If the Safety Doorswitch E is switched on the system is supplied with electrical current After you use Safety Doorswitch E the system will always start in Manual mode If you want to open the control box you must switch off Safety Doorswitch E or else the door cannot be opened This is an additio...

Страница 13: ...e the drum check the seal between the partition and the flange of the drum The high pressure pump does not work The plug is not plugged into the right power socket spray pump 12 Winterising To ensure proper functioning of the system do not allow the water temperature to decrease below 4 degrees Celsius Measures that you can take Place a cover or lid over the drain The control and motor cannot with...

Страница 14: ...14 Combi drum 35 pump 16 Technical diagram ...

Страница 15: ...15 www filtreco nl 17 Diagram for assembly in a pond P ...

Страница 16: ...16 Filtreco Nusterweg 69 NL 6136 KT Sittard The Netherlands CoC 14052952 VAT NL 58 28 235 B01 31 46 457 25 55 info filtreco nl www filtreco nl Filtreco is a WTH B V brand ...

Отзывы: