![Filtration Group Pi 210 Series Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/filtration-group/pi-210-series/pi-210-series_manual_2288863085.webp)
Pi 4700 NG 40 up to 400
5
7.2 Filter elements*
Nominal size
NG [l/min]
Order
number
Type
Filter
material
max.
∆
p
[bar]
Filter surface
[cm²]
77940638
Pi 71016 DN PS vst 3
PS vst 3
77960123
Pi 72016 DN PS vst 6
PS vst 6
77925688
Pi 73016 DN PS vst 10
PS vst 10
78269797
Pi 74016 DN PS vst 16
PS vst 16
160
78216178
Pi 75016 DN PS vst 25
PS vst 25
210
1885
77940646
Pi 71025 DN PS vst 3
PS vst 3
77960115
Pi 72025 DN PS vst 6
PS vst 6
77925696
Pi 73025 DN PS vst 10
PS vst 10
78269813
Pi 74025 DN PS vst 16
PS vst 16
250
78216186
Pi 75025 DN PS vst 25
PS vst 25
210
3090
77940653
Pi 71040 DN PS vst 3
PS vst 3
77960107
Pi 72040 DN PS vst 6
PS vst 6
77930829
Pi 73040 DN PS vst 10
PS vst 10
78269821
Pi 74040 DN PS vst 16
PS vst 16
400
78260903
Pi 75040 DN PS vst 25
PS vst 25
210
5240
* a wider range of element types ia available on request
8. Technical specifications
Design:
line mounting filter
Nominal
pressure:
Pi
47016-47040
315 bar (4480 psi)
Pi 47004-Pi 47010
350 bar (4980 psi)
Test pressure: Pi 47016-47040
410 bar (5830 psi)
Pi 47004-Pi 47010
455 bar (6470 psi)
Temperature range:
-10 °C to +120 °C
(other temperature ranges on request)
Filter head material:
St
Filter housing material:
St
Sealing material:
NBR/PTFE
Maintenance indicator setting:
∆
p 5 bar
±
10 %
Electrical data of maintenance indicator:
Max. voltage:
250 V AC/200 V DC
Max. current:
1 A
Contact load:
70 W
Type of protection:
IP 65 in inserted and
secured status
Contact:
normally open/closed
Cable sleave:
M20x1.5
The switching function can be changed by turning the electric upper
part by 180° (normally closed contact or normally open contact). The
state on delivery is a normally closed contact. By inductivity in the
direct current circuit the use of suitable protection circuit should be
considered. Further maintenance indicator details and designs are
available in the maintenance indicator data sheet.
-
We draw attention to the fact that all values indicated are average
values and do not always occur in specific cases of application. Our
products are continually being further developed. Values, dimen-
sions and weights can change as a result of this. Our specialized
department will be pleased to offer you advice.
-
We recommend you to contact us concerning applications of our fil-
ters in areas governed by the EU Directive 94/9 EC (ATEX 95). The
standard version can be used for liquids based on mineral oil (cor-
responding to the fluids in Group 2 of Directive 97/23 EC Article 9).
If you consider to use other fluids please contact us for additional
support.
_
Subject to technical alteration without prior notice.