7.2 Filter elements*
Nominal size
NG [l/min]
Order number
Type
Filter material
max.
∆
p
[bar]
Filter
surface
[cm²]
78227514
Pi 21025 DN PS 3
PS 3
4020
77960834
Pi 22025 DN PS 6
PS 6
4020
77925613
Pi 23025 DN PS 10
PS 10
4020
78261075
Pi 24025 DN PS 16
PS 16
4020
78261083
Pi 25025 DN PS 25
PS 25
20
4020
77940646
Pi 71025 DN PS vst 3
PS vst 3
3090
77960115
Pi 72025 DN PS vst 6
PS vst 6
3090
77925696
Pi 73025 DN PS vst 10
PS vst 10
3090
78269813
Pi 74025 DN PS vst 16
PS vst 16
3090
250
78216186
Pi 75025 DN PS vst 25
PS vst 25
210
3090
78227522
Pi 21 040 DN PS 3
PS 3
6770
77960842
Pi 22 040 DN PS 6
PS 6
6770
77925621
Pi 23 040 DN PS 10
PS 10
6770
78261109
Pi 24 040 DN PS 16
PS 16
6770
78261117
Pi 25 040 DN PS 25
PS 25
20
6770
77940653
Pi 71 040 DN PS vst 3
PS vst 3
5240
77960107
Pi 72 040 DN PS vst 6
PS vst 6
5240
77930829
Pi 73 040 DN PS vst 10
PS vst 10
5240
78269821
Pi 74 040 DN PS vst 16
PS vst 16
5240
400
78260903
Pi 75 040 DN PS vst 25
PS vst 25
210
5240
*a wider range of elemens is available on request
8. Technical specifications
Design:
line mounting filter
Nominal pressure:
Pi 21004-21010
LEER
10^7 load changes
63 bar (900 psi)
Pi 21016-21040
10^7 load changes
25 bar (360 psi)
2x 10^6 load changes
32 bar (460 psi)
Test pressure:
Pi 21004-21010
95 bar (1370 psi)
Pi 21016-21040
48 bar (690 psi)
Temperature range:
-10 °C to +120 °C
survival temperature - 40 °C
(other temperature ranges on request)
Bypass setting:
∆
p 3.5 bar
±
10 %
Filter head material:
GAL
Filter housing material:
AL/St.
Sealing material:
NBR/AL
Maintenance indicator setting:
∆
p 2.2 bar
±
10 %
Electrical data of maintenance indicator:
Max. voltage:
250 V AC/200 V DC
Max. current:
1 A
Contact load:
70 W
Type of protection:
IP 65 in inserted and
secured status
Contact:
normally open/closed
Cable connection:
M20x1.5
The switching function can be changed by turning the electric upper
part by 180° (normally closed contact or normally open contact). The
state on delivery is a normally closed contact. By inductivity in the
direct current circuit the use of suitable protection circuit should be
considered. Further maintenance indicator details and designs are
available in the maintenance indicator data sheet.
-
We draw attention to the fact that all values indicated are average
values which do not always occur in specific cases of application.
Our products are continually being further developed. Values, di-
mensions and weights can change as a result of this. Our special-
ized department will be pleased to offer you advice.
-
We recommend to contact us concerning applications of our filters in
areas governed by the EU Directive 94/9 EC (ATEX 95). The stand-
ard version can be used for liquids based on mineral oil (correspond-
ing to the fluids in Goup 2 of Directive 97/23 EC Article 9). If you
consider to use other fluids please contact us for additional support.
LEER
Subject to technical alteration without prior notice.