![FilterSense DynaCHARGE PM 1 PRO-A Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/filtersense/dynacharge-pm-1-pro-a/dynacharge-pm-1-pro-a_installation-and-operating-manual_2288826035.webp)
PM 1 Installation and Operating Manual v1.2
35
FilterSense © 2016
10 Maintenance
Only trained professionals should install/maintain this product.
Shutdown processes that include high temperatures, high pressures, toxic
gases, hazardous particulate, or explosion risks prior to installing or removing
equipment.
Electronics Module
normally drift free and require no periodic maintenance or electronics calibration
by the user. Electronics calibration is automatically confirmed with PRO models equipped with device health
checks or EPA automatic self tests. As desired or required for quality programs or regulations, the entire device
or the electronics module may be returned to the factory for NIST traceable calibration certification.
Particulate Sensor
not require periodic
maintenance other than an annual inspection. This should be verified by conducting functional verification
checks of the electronics and manually inspecting the sensor after one and six months of operation. After these
two initial checks, if no need for sensor maintenance is observed, an annual inspection is recommended. For EPA
compliance and critical measurement applications, PRO models with device health checks and EPA automatic
self tests are recommended to provide added assurance between annual inspections and to automate
regulatory inspection requirements.
Particulate Monitor Inspection
Each inspection should consist of the following:
Visually inspect inside the sensor enclosure.
Remove the sensor from the process and inspect the probe and insulator for buildup and/or moisture.
o
The sensor probe and insulator may be wiped down with a damp rag.
o
Fully insulated probes are recommended for processes with moisture and most conductive
particulates.
Inspect the inside of the process mount for buildup and/or moisture.
Check the outputs.
Perform
checks.