Chapter 3: Repair & Replacement Procedures
Industrial Dynamics Company, Ltd. ©
Form 42600 (10/03)
3-9
2. Remove the entire Base inspection strobe assembly.
3. Remove the baffle by loosening the four screws holding it in place.
4. Loosen the two screws holding the upper reflective plate.
5. Pull out the existing flash tube (Item #14) from the base.
6. Before inserting the replacement flash tube, fill each banana socket
with DC4 compound (or equivalent) to keep out moisture.
CAUTION
Do not touch the replacement flash tube with bare hands. Plastic
gloves are supplied. Do not let the flash tube become contaminated
with any foreign materials. Contamination on the flash tube may
cause damage to the tube and/or shorten its effective life. If the lamp
is touched with fingers or is contaminated, make sure you wipe the
lamp clean using a glass cleaning solution and lens tissue or soft cloth
before installation.
7. Without removing the protective plastic bags, gently insert the new
flash tube’s banana plugs into their matching sockets.
8. Remove the plastic bag from each lamp.
9. Reassemble the remaining parts and re-install the assembly into the
machine.
INSPECTION HEAD
Due to the interrelationships between cameras, optical components,
servos and the inspection software, certain replacement procedures must
be performed by an authorized, factory-trained IDC Representative.
These include replacing:
•
Base Inspection camera/optics
•
Base camera zoom and brightness servos
•
IR RLD camera/optics
•
Finish Inspection camera/optics
•
Inner Sidewall Inspection camera/optics
•
Thread Inspection camera/optics
•
Camera zoom and brightness servos
If you suspect any of these components require replacement, contact your
designated authorized IDC Representative for assistance.
Finish Lens
To replace the Finish Lens Protector proceed as follows: