OV-II Maintenance, Troubleshooting and Service Manual
2-10
Industrial Dynamics Company, Ltd. ©
Form 42600 (10/03)
On the Outer Sidewall:
•
Heavy scuffing
•
Extreme color variations
•
Large air bubbles
•
Heavy embossed lettering or molding
•
Prominent seams
3. Access the
STATUS > REJECT HISTORY
screen and watch the
DETECT COUNTS
on the left for each inspection system. Decide
which inspection system is detecting unusually high numbers of
bottles:
If more than one system is recording extraordinarily high numbers of
false rejects, temporarily turn OFF the Omnivision's rejector by moving
the cursor to the
MACHINE CONFIGURATION > REJECT
HANDLING
function and pressing the
Master Reject Enable
button.
When a single inspection system's rejection capability is turned OFF, all
other systems continue to inspect and reject. If the
REJECT MASTER
function is turned OFF, ALL inspection systems continue to inspect, but
NO REJECTS WILL TAKE PLACE
.
NOTE
Consult your supervisor before turning OFF any inspection system's
rejection capability or turning OFF the Omnivision's main rejector.