FT-70 Fill Level Inspector Service Manual
1-8
Inspection Accuracy
The basic fill level inspection accuracy is
±
0.4 mm. The accuracy
obtained during production will degrade based on glass or plastic
quality, liquid motion, foam, and conveyor speed.
The FT-70 can maintain accuracy at conveyor speeds up to 350
feet/minute (107 meters/minute) with a maximum velocity
change of 15:1 (encoder versions only). The actual rate will vary
depending upon the product density, container density, container
size and shape, and container spacing.
Physical Size
The FT-70 is available in three sizes based on the dimensions of the
inspection tunnel. Larger containers require a larger inspection
tunnel. The size of your FT-70 was specified when you placed your
order.
Containers/Minute
Feet/Minute (m/min)
Accuracy
600
135 (41)
±
0.06 inch (1.6 mm)
1200
270 (83)
±
0.12 inch (3.1 mm)
2200
500 (152)
±
0.21 inch (6.0 mm)
Standard
Wide
Extra Wide
Tunnel Width
4.5 inches
(115 mm)
5.5 inches
(141 mm)
7.5 inches
(192 mm)
Tunnel Height
9 inches
(230 mm)
9 inches
(230 mm)
9 inches
(230 mm)
Overall Width
25.25 inches
(641 mm)
26.25 inches
(667 mm)
28.25 inches
(717 mm)
Overall Height
18 inches
(457
mm)
18 inches
(457
mm)
18 inches
(457
mm)
Overall Depth
4 inches
(102 mm)
4 inches
(102 mm)
4 inches
(102 mm)
Max. Can Width
at Trigger
2.125 inches
(54 mm)
3.125 inches
(80 mm)
5.125 inches
(130 mm)
Max. Can Width
at Fill Level
3.25 inches
(83 mm)
6.25 inches
(159 mm)
6.25 inches
(159 mm)
Minimum Fill Level
1.25 inches
(32 mm)
1.25 inches
(32 mm)
1.25 inches
(32 mm)
Industrial Dynamics Company, Ltd. ©
Form 4017 (6/00)
Industrial Dynamics Company, Ltd. ©
40256-0600
Содержание FT-70c
Страница 1: ...FT 70c Service and Technical 40256 0600 Reference Manual for Can Inspection...
Страница 14: ...Table of Contents XIII Industrial Dynamics Company Ltd Form 40256 0600...
Страница 21: ...FT 70 Fill Level Inspector Service Manual 1 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 33: ...FT 70 Fill Level Inspector Service Manual 1 14 Industrial Dynamics Company Ltd 40256 0600...
Страница 35: ...FT 70 Fill Level Inspector Service Manual 2 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 39: ...FT 70 Fill Level Inspector Service Manual 2 6 Industrial Dynamics Company Ltd 40256 0600...
Страница 41: ...FT 70 Fill Level Inspector Service Manual 3 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 69: ...FT 70 Fill Level Inspector Service Manual 3 30 Industrial Dynamics Company Ltd 40256 0600...
Страница 71: ...FT 70 Fill Level Inspector Service Manual 4 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 139: ...FT 70 Fill Level Inspector Service Manual 5 44 Industrial Dynamics Company Ltd 40256 0600...
Страница 141: ...FT 70 Fill Level Inspector Service Manual 6 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 183: ...FT 70 Fill Level Inspector Service Manual 7 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 225: ...FT 70 Fill Level Inspector Service Manual 9 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 233: ...FT 70 Fill Level Inspector Service Manual 10 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 243: ...FT 70 Fill Level Inspector Service Manual 10 12 Industrial Dynamics Company Ltd 40256 0600...