FT-70 Fill Level Inspector Service Manual
6-14
9.
Press Key 5 until CAN WIDTH AT TRIG appears and enter (in
millimeters) the production container’s width at the trigger
point.
10.
Measure the diameter of the container (in millimeters) at its
widest point. This is the containers maximum diameter.
11.
Press Key 5 until MAXIMUM CAN DIAMETER appears and
enter (in millimeters) the production container’s maximum
diameter.
Executing the Encoder Calibration Routine
Use the largest possible opaque container when executing the
Calibrate Encoder Routine. The larger and more opaque the
container, the greater the accuracy of the sensor readings. For
example, if the test container diameter is 28 mm, the calculation
error factor is
±
2 teeth. If the test container diameter is 66 mm, the
calculation error factor is
±
1 tooth.
Note
Slipping a short piece of pipe over the container neck is a useful
way to increase the width of the can at the trigger point. If you
choose to do this, you must repeat step 9 in order to enter the pipe
diameter.
12.
Open dip switch S1-6.
13.
Start the conveyor and run it at the highest expected
production speed. You may not be able to achieve the highest
possible speed unless the filler unit is running.
14.
Press Key 5 until CALIBRATE ENCODER appears and press
the Arrow Key to execute the encoder calibration routine. This
procedure takes several seconds to complete. When READY is
displayed, proceed to the following step.
15.
Place the container on the conveyor upstream of the FT-70 so
the container passes through the inspection tunnel without
slipping. The FT-70 automatically calculates the prescaler
value. It takes several seconds for the FT-70 to make this calcu-
lation. When RUN 16 CONTAINERS appears, proceed to the
following step.
Industrial Dynamics Company, Ltd. ©
40256-0600
Содержание FT-70c
Страница 1: ...FT 70c Service and Technical 40256 0600 Reference Manual for Can Inspection...
Страница 14: ...Table of Contents XIII Industrial Dynamics Company Ltd Form 40256 0600...
Страница 21: ...FT 70 Fill Level Inspector Service Manual 1 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 33: ...FT 70 Fill Level Inspector Service Manual 1 14 Industrial Dynamics Company Ltd 40256 0600...
Страница 35: ...FT 70 Fill Level Inspector Service Manual 2 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 39: ...FT 70 Fill Level Inspector Service Manual 2 6 Industrial Dynamics Company Ltd 40256 0600...
Страница 41: ...FT 70 Fill Level Inspector Service Manual 3 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 69: ...FT 70 Fill Level Inspector Service Manual 3 30 Industrial Dynamics Company Ltd 40256 0600...
Страница 71: ...FT 70 Fill Level Inspector Service Manual 4 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 139: ...FT 70 Fill Level Inspector Service Manual 5 44 Industrial Dynamics Company Ltd 40256 0600...
Страница 141: ...FT 70 Fill Level Inspector Service Manual 6 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 183: ...FT 70 Fill Level Inspector Service Manual 7 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 225: ...FT 70 Fill Level Inspector Service Manual 9 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 233: ...FT 70 Fill Level Inspector Service Manual 10 2 Industrial Dynamics Company Ltd 40256 0600...
Страница 243: ...FT 70 Fill Level Inspector Service Manual 10 12 Industrial Dynamics Company Ltd 40256 0600...