![Filtec ft-70 Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/filtec/ft-70/ft-70_operation-manual_2288788074.webp)
Chapter 4: Diagnostics and Troubleshooting
4-13
Troubleshooting Procedures
The troubleshooting procedures in this section are designed to
help you quickly correct simple problems with your FT-70/75. If
problems persist, or if advanced troubleshooting is required,
contact your Service Department.
Before you attempt any diagnostic or troubleshooting procedure:
•
Read and understand the procedure(s) thoroughly.
•
Understand and comply with all safety precautions.
•
If you cannot correct the problem, contact your service
department.
Is the power turned on
Verify that both the main power switch on the I/O Junction
Box and the internal power switch located on the power filter
junction box are turned on.
Is the power filter circuit breaker tripped
The internal power switch is an integrated switch/circuit
breaker. When the breaker is tripped, the power switch turns
off. If you are certain power is reaching the FT-70/75, however
the unit will not power up, contact your Service Department.
Is the X-ray Source Function enabled
If the X-ray Source Function is turned off, Error 123 appears
and the beacon flashes to indicate that inspection can not
commence until the X-ray Generator is enabled.
The display does not respond when keys are pressed
1.
Turn the FT-70/75’s main power switch off.
2.
Press and hold the reset button while turning the main power
switch back on. Wait for the three beeps before releasing the
Reset Button.
3.
Inspect the control panel display touchpad for water damage.
If moisture is present, contact your Service Department.
The display shows a blinking cursor and the beacon is on
Check to be sure the reset switch is not stuck.
Industrial Dynamics Company, Ltd. Document 40274-0600
Содержание ft-70
Страница 1: ...FT 70 and FT 75 Operation Guide 40274 0600...
Страница 2: ...FT 70 and FT 75 Operation Guide Document 40274 0600 Fill Level Inspectors...
Страница 13: ...FT 70 75 Fill Level Inspectors Operator s Guide XII Industrial Dynamics Company Ltd Document 40274 0600...
Страница 15: ...FT 70 75 Fill Level Inspectors Operator s Guide 1 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 21: ...FT 70 75 Fill Level Inspectors Operator s Guide 1 8 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 23: ...FT 70 75 Fill Level Inspectors Operator s Guide 2 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 45: ...FT 70 75 Fill Level Inspectors Operator s Guide 2 24 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 47: ...FT 70 75 Fill Level Inspectors Operator s Guide 3 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 61: ...FT 70 75 Fill Level Inspectors Operator s Guide 3 16 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 79: ...FT 70 75 Fill Level Inspectors Operator s Guide 5 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 85: ...FT 70 75 Fill Level Inspectors Operator s Guide 5 8 Industrial Dynamics Company Ltd Document 40274 0600...