FT-70/75 Fill Level Inspectors Operator’s Guide
2-10
3.
Center a properly filled and capped production container in
the inspection tunnel so that it is directly under the missing cap
sensor.
4.
Find your type of missing cap sensor in the table below and
adjust the upper jam nut to raise or lower the sensor to the
proper height.
5.
When you achieve the proper height, tighten the lower jam nut
to secure the sensor positioning.
6.
If you will not be performing further alignment procedures,
reactivate the X-ray Generator. For more information see “The
Safety Interlock Switch” on page 2-4.
Description (Cap Type)
Maximum Height Above Cap
Nonferrous (Aluminum)
0.4 inch (10 mm)
Photo-Optic Sensor (All)
0.7 inch (18 mm)
Extended Range (Aluminum)
Extended Range (Steel)
0.5 inch (13 mm)
0.88 inch (22 mm)
Steel Cap Under Aluminum Foil
0.3 inch (8 mm)
Standard
0.25-0.38 inch (6-9 mm)
Bifurcated fiber-optic Sensor
0.7 inch (18 mm)
Industrial Dynamics Company, Ltd. Document 40274-0600
Содержание ft-70
Страница 1: ...FT 70 and FT 75 Operation Guide 40274 0600...
Страница 2: ...FT 70 and FT 75 Operation Guide Document 40274 0600 Fill Level Inspectors...
Страница 13: ...FT 70 75 Fill Level Inspectors Operator s Guide XII Industrial Dynamics Company Ltd Document 40274 0600...
Страница 15: ...FT 70 75 Fill Level Inspectors Operator s Guide 1 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 21: ...FT 70 75 Fill Level Inspectors Operator s Guide 1 8 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 23: ...FT 70 75 Fill Level Inspectors Operator s Guide 2 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 45: ...FT 70 75 Fill Level Inspectors Operator s Guide 2 24 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 47: ...FT 70 75 Fill Level Inspectors Operator s Guide 3 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 61: ...FT 70 75 Fill Level Inspectors Operator s Guide 3 16 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 79: ...FT 70 75 Fill Level Inspectors Operator s Guide 5 2 Industrial Dynamics Company Ltd Document 40274 0600...
Страница 85: ...FT 70 75 Fill Level Inspectors Operator s Guide 5 8 Industrial Dynamics Company Ltd Document 40274 0600...