![Fife SBPC-21-EN/IP Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/fife/sbpc-21-en-ip/sbpc-21-en-ip_instruction-manual_2288186031.webp)
SBPC-21-EN/IP CUSTOMER INSTRUCTION MANUAL
________________________________________________________________________________________________________________
12-20-2002
Figure Sheet 1-853-A
Page 25
5
C
ONTROL
I
NFORMATION
• • • • • •
CDP-01 Control Matrix
The CDP-01 parallel input matrix normally applied to the X7 port on the CDP-01. If the default matrix
using the SBPC-21-EN/IP, the CDP-01 parallel input matrix is connected to a time slice. This
connection allows serial commands to be used to control the CDP-01 instead of the hardware parallel
input. The commands described in the control matrix tables on the following pages apply to the
commands issued from Ethernet to FifeNet over the network via Data Word 1 in Table 4-1.
External Lock
There is one command, however, that the CDP-01 firmware will not accept over a serial connection for
safety reasons. This command is “External Lock.” Even though the CDP-01 matrix has the parallel
inputs mapped to a FifeNet time slice, the External Lock command is still activated by the matrix
shown below when this condition appears on the X7 port of the CDP-01. For multidrive CDP-01’s, the
command is applied to all drive present.
CDP-01 Parallel Input Matrix for Use with SBPC-21-EN/IP
Table 5-1
INPUTS
Command Via X7 Parallel Port
5
4
3
2
1
0
External Lock (All drives applicable.)
--
--
--
--
--
1
Single-Drive CDP-01
CDP-01 Matrix: 100246-02X
CDP-01 State Machine: 581000-020
SBPC-21-EN/IP Matrix: 100410-02X
CDP-01 Control Matrix
Table 5-2
COMMAND VIA NETWORK
HEX
DRIVE 1, AUTOMATIC
04
DRIVE 1, MANUAL
08
DRIVE 1, SERVO-CENTER
0C
DRIVE 1, JOG LEFT
10
DRIVE 1, JOG RIGHT
20
DRIVE 1, AUTO SETUP
30
DRIVE 1, RGPC SHIFT LEFT
18
DRIVE 1, RGPC SHIFT RIGHT
28
DRIVE 1, RGPC RESET
38
DRIVE 1, SENSOR EDGE LEFT
14
DRIVE 1, SENSOR EDGE RIGHT
24
DRIVE 1, SENSOR EDGE CENTER
34
DRIVE 1, SENSOR LINE CENTER
1C
DRIVE 1, SENSOR LINE EDGE
2C
DRIVE 1, SENSOR LINE E&C
3C