PAGE 0
Item
DEC
Item
HEX
Signal Condition Read/Write
Johnson
Tag
Description
44 2C
-
-
Spare
45 2D
-
-
Spare
46 2E
Byte
Write
PV1@
Process variable connection
47 2F
Byte
Write
RS1@
Remote setpoint connection
48
30 Byte
Write
RV1@
Reference variable connection
49
31 Byte
Write
PB1@
Proportional band connection
50
32 Byte
Write
OF1@
OFF mode logic control connection
51
33 Byte
Write
SB1@
STAND-BY mode logic control
connection
52
34 Byte
Write
RA1@
Reverse action logic control connection
53
35 Byte
Write
EF1@
External forcing logic control
connection
54
36 Byte
Write
TYPE1
Controller type
55
37 FP
Write
LS1
Local setpoint
56
38 FP
Write
PB1
Proportional band
57
39 FP
Write
TI1
Reset action
58 3A
FP
Write
TD1
Rate action
59 3B
FP
Write
HL1
Upper limit of the control output
60 3C
FP
Write
LL1
Lower limit of the control output
61 3D
FP
Write
BS1
Change of setpoint during STAND-BY
62 3E
FP
Write
BO1
Change of setpoint during OFF
63 3F
FP
Write
AD1
Deviation alarm
64
40 Byte
Write
PV2@
Process variable connection
65
41 Byte
Write
RS2@
Remote setpoint connection
66
42 Byte
Write
RV2@
Reference variable connection
67
43 Byte
Write
PB2@
Proportional band connection
68
44 Byte
Write
OF2@
OFF mode logic control connection
69
45 Byte
Write
SB2@
STAND-BY mode logic control
connection
70
46 Byte
Write
RA2@
Reverse action logic control connection
71
47 Byte
Write
EF2@
External forcing logic control
connection
72
48 Byte
Write
TYPE2
Controller type
73
49 FP
Write
LS2
Local setpoint
74 4A
FP
Write
PB2
Proportional band
75 4B
FP
Write
TI2
Reset action
76 4C
FP
Write
TD2
Rate action
77 4D
FP
Write
HL2
Upper limit of the control output
78 4E
FP
Write
LL2
Lower limit of the control output
78 4E
FP
Write
LL2
Lower limit of the control output
79 4F
FP
Write
BS2
Change of setpoint during STAND-BY
80
50 FP
Write
BO2
Change of setpoint during OFF
81
51 FP
Write
AD2
Deviation alarm
82
52 Byte
Write
PV3@
Process variable connection
83
53 Byte
Write
RS3@
Remote setpoint connection
84
54 Byte
Write
RV3@
Reference variable connection
85
55 Byte
Write
PB3@
Proportional band connection
86
56 Byte
Write
OF3@
OFF mode logic control connection
87
57 Byte
Write
SB3@
STAND-BY mode logic control
connection
88
58 Byte
Write
RA3@
Reverse action logic control connection