Maintenance
FDN 3025-A
5. MAINTENANCE
Make sure that the machine is not live when carrying out maintenance work on the
motor.
This machine has been designed to operate over a long period of time with a minimum of maintenance.
Continuous satisfactory operation depends upon proper machine care and regular cleaning.
Malfunction
Should the machine fail to function correctly, a number of possible causes and the appropriate solutions are given
below:
In case a staple or nail is jammed in the tool, follow the procedure below:
Place the machine in “0” position (4).
Open the cartridge shaft (2) by pulling the reload lever (1) and let the jammed nails/staples fall out.
Reload the machine, see chapter “ Loading the nails or staples” for instructions.
Test the machine on a piece of scrap.
Cleaning
Regularly clean the device’s casing with a soft cloth, preferably after each use. Keep the fan slits free of dust and
dirt. Remove tough dirt using a soft cloth, dampened with soapy water. Do not use solvents such as benzene,
alcohol, ammonia, etc., which might damage the plastic parts.
For the charger
Intended use
This tacker has an integrated lithium-ion battery, which you can charge with the included USB charging cable
(USB-mains adapter not included).
a)
The appliance is not to be used by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction.
b)
Children being supervised not to play with the appliance.
c) Do not recharge non-rechargeable batteries!
d) During charging, batteries must be placed in a well ventilated area!
e)
Integrated batteries may only be removed for disposal by qualifi ed personnel.
Opening the housing shell can destroy the power tool. To remove the battery from the power tool, press
the On/Off switch (4) until the battery is fully discharged. Unscrew the screws on the housing and remove
the housing shell in order to remove the battery. To prevent a short circuit, disconnect the connectors on
the battery one at a time and then isolate the poles. Even when fully discharged, the battery still contains a
residual capacity, which can be released in case of a short circuit.
Содержание FDN 3025-A
Страница 1: ...FDN 3025 A...
Страница 2: ...2 FDN 3025 A...
Страница 3: ...3 C D 1 2...
Страница 4: ...4 FDN 3025 A E 98 B 8...
Страница 18: ...EN 18 FDN 3025 A...
Страница 32: ...CZ 32 FDN 3025 A...
Страница 46: ...SK 46 FDN 3025 A...
Страница 60: ...HU 60 FDN 3025 A...
Страница 75: ......
Страница 76: ......
Страница 78: ......
Страница 79: ......
Страница 80: ......