background image

EN

20V AIR COMPRESSOR

USER’S MANUAL

9

GENERAL SAFETY RULES

or footing and may become damaged.

  Use the infl ator only for its intended use. Do not alter or modify the unit from the original design or function.
  Always be aware that misuse and improper handling of this infl ator can cause injury to yourself and others.
  Never leave an infl ator unattended with the air hose attached to the item being infl ated.
  Do not continue to use a infl ator or hose that leaks air or does not function properly.
  Always disconnect the air supply and power supply before making adjustments, servicing an infl ator, or 

when an infl ator is not in use.

  Do not attempt to pull or carry the infl ator by the hoses.
  Always follow all safety rules recommended by the manufacturer of your infl ator, in addition to all safety 

rules for the infl ator. 

Following this rule will reduce the risk of serious personal injury.

  Do not use infl ator as a breathing device.
  Never direct a jet of compressed air toward people or animals. Take care not to blow dust and dirt towards 

yourself or others. 

Following this rule will reduce the risk of serious injury.

  Protect your lungs. 

Wear a face or dust mask if the operation is dusty. Following this rule will reduce the risk 

of serious personal injury.

  Do not use this infl ator to spray chemicals. 

Your lungs can be damaged by inhaling toxic fumes.

  Check damaged parts. Before further use of the infl ator or air tool, a guard or other part that is damaged 

should be carefully checked to determine that it will operate properly and perform its intended function. 
Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, and any other 
conditions that may affect its operation. A guard or other part that is damaged should be properly repaired 
or replaced by an authorized service center. 

Following this rule will reduce the risk of shock, fi re, or serious 

injury.

  Inspect tool cords periodically and, if damaged, have repaired at your nearest Authorized Service Center. 

Constantly stay aware of cord location. 

Following this rule will reduce the risk of electric shock or fi re.

  Risk of Bursting. 

Carefully monitor objects during infl ation.

  To reduce the risk of over infl ation, 

use a reliable pressure gauge periodically during infl ation. The pressure 

gauge on the infl ator is for reference only and is therefore not binding for exact values.

  Never leave the infl ator unattended during infl ation.
  Allow pump to cool 

for ten (10) minutes after each ten (10) minutes of continuous use. Never block the 

infl ating or defl ating outlets while operating.

  Save these instructions. 

Refer to them frequently and use them to instruct others who may use this infl ator. 

If you loan someone this infl ator, loan them these instructions also to prevent misuse of the product and 
possible injury.

Содержание 50004955

Страница 1: ...FDAK 70205 0...

Страница 2: ...20V AIR COMPRESSOR USER S MANUAL 3 2 1 3...

Страница 3: ...4 FDAK 70205 0 4 5 6 7 8 9...

Страница 4: ...20V AIR COMPRESSOR USER S MANUAL 5 10 11 12 13 14 15...

Страница 5: ...re use WARNING To reduce the risk of injury the user must read and understand the operator s manual before using this product If you do not understand the warnings and instructions in the operator s m...

Страница 6: ...ries PERSONAL SAFETY Stay alert watch what you are doing and use common sense when operating an in ator Do not use in ator while tired or under the in uence of drugs alcohol or medication A moment of...

Страница 7: ...f control and deterioration of the enclosure plastic GENERAL SAFETY RULES Never point any in ator toward yourself or others Keep the exterior of the in ator dry clean and free from oil and grease Alwa...

Страница 8: ...ls Your lungs can be damaged by inhaling toxic fumes Check damaged parts Before further use of the in ator or air tool a guard or other part that is damaged should be carefully checked to determine th...

Страница 9: ...property damage Some of the following symbols may be used on this product Please study them and learn their meaning Proper interpretation of these symbols will allow you to operate the product better...

Страница 10: ...applications ACCESSORIES STORAGE Accessories provided with the in ator can be placed in the storage area located on the right side of the tool DIGITAL GAUGE The digital gauge measures and displays th...

Страница 11: ...o breakage or damage occurred during shipping Do not discard the packing material until you have carefully inspected and satisfactorily operated the product PACKING LIST 20V air compressor Tapered Ada...

Страница 12: ...cool down time are required WARNING Since the pressure gauge is not calibrated and is therefore not binding for exact values tire pressure must be checked using a reliable measuring device before driv...

Страница 13: ...n ating high pressure items like tires and sports balls The low pressure hose is designed for in ating or de ating low pressure high volume items like air rafts mattresses and oats NOTE Pressure gauge...

Страница 14: ...ed to the end of the low pressure hose The pinch valve adaptor is used for items that have a smaller air opening or pinch valve Insert pinch valve adaptor into pinch valve insuring that the tip of the...

Страница 15: ...rs to in ate a variety of items To install accessory insert adaptor or needle into air chuck and push air chuck clamp down until it locks into place In ate to desired pressure Remove accessory by lift...

Страница 16: ...e To use the Presta valve adaptor Loosen Presta valve locking nut Thread Presta valve adaptor onto valve stem with larger open end toward wheel Position the air chuck clamp in the unlock position Clam...

Страница 17: ...se etc WARNING Do not at any time let brake uids gasoline petroleum based products penetrating oils etc come in contact with plastic parts Chemicals can damage weaken or destroy plastic which can resu...

Страница 18: ...switch II Fig 6 A Power switch Fig 7 A Low pressure hose B Pitch valve adaptor Fig 8 A De ator Fig 9 A Valve stem B Air chuck C Air hose D To lock E To unlock F Air chuck clamp Fig 10 A Presta valve...

Страница 19: ...t the indicator light is lit If it is not lit check that the power plug of the charger is correctly plugged into the socket If it is check the socket s fuse circuit breaker 4 The body of the device he...

Страница 20: ...recycling Alternatively in some countries of the European Union or other European countries you can return your products to your local dealer when you buy an equivalent new product By dutiful disposa...

Страница 21: ...EN 22 FDAK 70205 0 ACCESSORIES 10 ACCESSORIES Item number Accessory FDUZ 79020 Battery pack 2 Ah FDUZ 79040 Battery pack 4 Ah FDUZ 79100 Fast charger FDUZ 79110 Fast dual charger...

Отзывы: