Step 5: Slide the pre-filter into the

pre-filter frame from the bottom. 

Then place the bottom of the 

pre-filter frame into the slots on 

the bottom of the appliance and 

press the top towards the appliance. 

Pre-filter

MAINTENANCE INSTRUCTIONS

To increase the life of the air purifier, perform regular maintenance and 

care. Before performing maintenance, be sure to shut down the air purifier 

and unplug the power plug from the power source.

The TRIO Plus S calculates the recommended replacement of the filter based 

on operation time and fan speed. If the unit is run at higher speeds, the filters 

will likely capture more particles, and require replacement earlier than if the 

purifier was run at low speeds, filtering less air. 

It is recommended that the filter kit (Pre-filter, HEPA filter) be replaced every 6 

months of operation

Filter Indicator Timing

Step 6: Place front cover on the unit once 

all the filters have been installed. 

Slide the front cover slots on the base

into the slots on the appliance (direction 2) 

and then push the top towards the unit until 

the cover clicks closed.

1-3 Months

Every 6 months of 

operation

Remove front panel and clean 

pre-filter screen

Replace filter Kit: Pre-filter, HEPA

(Not the pre-filter framed screen)

Filter Kit # 602604600 (kit contains 

all required filters for replacement)

Maintenance Period

Replacement Parts

HEPA filters is best replaced every 3 to 6 months, depending on the 

use situation. High-efficiency HEPA filters and pre-filters cannot be

washed.

12

11

Содержание TRIO Plus S

Страница 1: ...TRIO Plus S TRIO PLUS S AIR CLEANER READ AND SAVE THESE INSTRUCTIONS USER MANUAL ...

Страница 2: ...with a polarized plug one blade is wider than the other To reduce the risk of electric shock this plug is intended to fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician Do not attempt to defeat this safety feature Do not use the appliance if the power cord or plug is broken damaged and or def...

Страница 3: ...Air Quality Indicator PRODUCT MODEL Rated Voltage V Rated Power W Frequency Hz CADR Rating CFM Airflow CF Weight Dimensions W x H x D inches Plus s 350 504 Sound dBA 53 26 2 17 3 x 28 x 9 90 120 60 04 03 HEPA Filter Pre filter Filter Cover Control Panel PM Sensor ...

Страница 4: ...nd the information they provide is not intended to diagnose treat cure or prevent any disease or condition Consult your doctor if you are unsure what levels of particulate matter are safe for you and visit www airnow gov for more information on particulate matter and all aspects of air pollution Air Speed Air Quality Indicator Poor 5 Red Unhealthy 4 Orange Fair 3 Yellow Good 2 Green Healthy 1 Blue...

Страница 5: ...ss turned off or switched to another mode When the purifier is on cycle between modes by pressing the mode button In AUTO mode the air speed will be adjusted automatically between speeds 1 5 according to the air quality level The purifier is equipped with a light sensor and will scan the environmental light in AUTO mode The purifier will switch to SLEEP mode after being in dark surroundings for 5 ...

Страница 6: ...case in direction 2 Step 3 Remove each filter from appliance and remove from packaging Step 2 Press down on Pre filter screen tabs and pull outwards Remove packaged pre filter from pre filter screen frame and then remove filter from package Setting up the TRIO Plus S Before using the appliance remove all the packaging materials covering the filters and place the filters back into the appliance as ...

Страница 7: ...ement earlier than if the purifier was run at low speeds filtering less air It is recommended that the filter kit Pre filter HEPA filter be replaced every 6 months of operation Filter Indicator Timing Step 6 Place front cover on the unit once all the filters have been installed Slide the front cover slots on the base into the slots on the appliance direction 2 and then push the top towards the uni...

Страница 8: ...asps of the pre filter frame down releasing the frame then pull the pre filter towards you Pull the pre filter down and out of the frame Carefully place the used pre filter into disposable bag Save the Pre filter screen frame Cleaning of the Appliance Clean the air purifier once a month If the operating environment is poor increase the cleaning frequency Before cleaning turn off the appliance and ...

Страница 9: ...an the sensor cover Sensor may require opening and sensor to be carefully cleaned with a damp Q Tip Adjust the air purifier operating speed to high speed high levels of particles Problem Possible Causes Remedial Action COMMON PROBLEMS AND SOLUTIONS The appliance does not turn on If the power light is off the unit is 1 Not plugged in or 2 The filters or front panel is not installed correctly The pl...

Страница 10: ...ssible Causes Remedial Action Ambient Environmental Atmospheric Temperature Humidity Pressure This package includes an air purifying appliance and an instruction manual If parts are missing after unpacking please contact the after sales service staff The odor gradually disappears after running the appliance for a period Clean or replace the filters Remove the padding behind the lamp and ties at en...

Отзывы: