CAUTIONS

Use cautions when mounting components to surfaces 
that may have concealed wiring beneath the surface.

!

INSTALLATION

Before installing the EvenAir comfort system, turn off
all power to your HVAC system.

Read and follow all instructions carefully.

Follow all local electrical codes during installation. All
wiring must conform to local and national electrical 
codes.

i

ATTENTION INSTALLER

REMOVE SUBBASE

ATTACH SUBBASE TO WALL

Attach the subbase to an interior wall and about 5-feet above 
the floor as shown using the screws and wall anchors supplied. 
The wires to the dampers, 
HVAC equipment and the 
temperature sensor pass 
through the opening 
between the terminals.

Place a slotted screwdriver in the 
slots as shown and rotate to 
remove subbase from the 
thermostat housing.

INSTALLER SECTION

This manual is separated into two different sections: one for the Homeowner and one for the System Installer.

The Installer section contains setup and installation information of the thermostat with optional user 
settings available to the homeowner.

Read entire manual before installing EvenAir products.

When servicing EvenAir system or accessing products,
turn off all power to these items.

R

C

WOB

EQUIPMENT

Y

G

TS

COM

COM

CLS

CLS

OPN

OPN

Sleeping

Living

W2E/Y2

T21

TS

Nighttime Airflow Control is defaulted to ON. If 
bedrooms are located downstairs, consider turning this
option Off using the User Options if bedrooms are not 
on the same trunk.

Install and wire components to the thermostat. 
(see Wiring section)

Airflow Control Off Option 17 turns off Airflow Control.
The thermostat controls the system, dampers fully open, 
nighttime airflow control is disabled and airflow is no
longer displayed on the thermostat.

User Airflow Control can be enabled using Option 18.
User turns off automatic airflow control in the User 
Options. 

Place the thermostat on the subbase. Do not install 
batteries.

Turn power to the HVAC equipment On.

Check for Error Messages. (see Error Message section)

Set equipment options 1-5 if different than factory 
default settings. (see Installer Options section).

1)

3)

2)

4)

5)

Test the installation using the Installer Test Menu. 
(see Installer Test Menu section on page 13)

6)

Install batteries and set the time and day (see Installing
Batteries and Set Time and Day section)

7)

page 7 of 16

P/N 780101703 3/18 Rev A

Содержание EvenAir T21

Страница 1: ...OW to the sleeping and living areas in a home and provides remote access to your HVAC system using a smart phone tablet or PC The thermostat is installed in the downstairs living area a temperature se...

Страница 2: ...es on 24VAC from the HVAC equipment using the R and C wires Connects to the home WiFi network to provide remote access via the internet using smart phone tablet or PC FEATURES The airflow to the livin...

Страница 3: ...control feature This features allows the homeowner to change the airflow level as desired and hold that level indefinitely This feature needs to be enabled using Installer Option 18 The homeowner then...

Страница 4: ...Hold Vacant Changing the Setpoint Temperature The UP DOWN keys are used to change the setpoint temperature Tu Day Airflow Schedule MENU MODE Cool Set To AM Living Living Sleeping 5 Tu Day Airflow Sch...

Страница 5: ...ng User Option 1 to change the Night Schedule Start Time Default airflow level upstairs is 130 If a different airflow level is desired use User Option 4 to change the airflow level in heating and User...

Страница 6: ...s a User Option Nighttime Airflow Control Set the Nighttime Airflow in Heating will only show if Nighttime Airflow Control is ON Set the Nighttime Airflow in Cooling will only show if Nighttime Airflo...

Страница 7: ...anual before installing EvenAir products When servicing EvenAir system or accessing products turn off all power to these items R C WOB EQUIPMENT Y G TS COM COM CLS CLS OPN OPN Sleeping Living W2E Y2 T...

Страница 8: ...a the damper may be wired in parallel LEDs on the damper actuator indicate when the damper is fully open green or fully closed red When properly installed the dampers will never fully close Gas Electr...

Страница 9: ...nted circuit board and hand tighten screw The TS5 sensor can be installed in a single gang box or directly to the wall using the hardware provided HAND TIGHTEN Printed circuit board Brass washer Use 2...

Страница 10: ...4 Heating Stages Htg 0 1 or 2 1 Only displayed if HP selected in Option 1 14 15 16 17 18 19 21 20 22 23 Night Level LCD Backlight Airflow Control On or Off Enable User Airflow Control Up Stage Time Ma...

Страница 11: ...s used to display the next option The ENTER key is used to save options and return to normal thermostat operation The hidden BACK key is used to return to previous options and is located to the left o...

Страница 12: ...tomatic airflow control on or off If off the dampers fully open nighttime airflow options are disabled and airflow is no longer displayed on the thermostat 17 Airflow Control On or Off Factory Default...

Страница 13: ...ing Living Airflow Test Airflow Test NEXT NEXT Sleeping Living FAN ENTER FAN ENTER 03 04 Testing Heating Airflow Limits In TEST 3 the system is Off Touch to go to TEST 4 to activate heating Verify the...

Страница 14: ...ure sensor s Check for open wires or shortages ENTER AM Touch the UP DOWN keys to change the HOUR Touch NEXT CHANGE THE HOUR Touch the UP DOWN keys to change the MINUTE Touch NEXT CHANGE THE MINUTE To...

Страница 15: ...ting airflow to the sleeping area the airflow is actually directed to the living area and when directing the airflow to the living area the airflow is actually directed to the sleeping area Turn syste...

Страница 16: ...rols product visit www fieldcontrols com Field Controls Technical Support 1 800 742 8368 fieldtec fieldcontrols com Phone 252 522 3031 Fax 252 522 0214 www fieldcontrols com Field Controls LLC c Field...

Отзывы: