MAINTENANCE AND TROUBLESHOOTING

SPARE PARTS AND ACCESSORY LIST

Field Controls

Part Number

Model 

Number

Description

580011101

580011102

580011301
580011302
580011401
580011405
580011406

T21

T21WF

TS51
TS52

AMT

IS

DS

MD-#

MD-LxH

Programmable wired thermostat w/ airflow control for GE equipment with 1H/1C, 2H/1C or 1H/2C,
or HP equipment with 2H/2C
Programmable wired thermostat w/ airflow control for GE equipment with 1H/1C, 2H/1C or 1H/2C, 
or HP equipment with 2H/2C. WiFi Enabled
Wired temperature sensor for the sleep area. Single sensor installation.
Wired temperature sensor for the sleep area. Dual sensor installation.
Replacement modulating actuator control, 3 wire.
Replacement idler shaft for AMT and AMJ actuators.
Replacement drive shaft for AMT and AMJ actuators.
EvenAir Round Balance Damper, 3 Wire. Sizes - 4” - 20” diameter.
EvenAir Rectangular Balance Damper, 3 Wire. Sizes - 8”, 10” and 12” Heights, up to 24” Length.

DAMPER OPERATION

Problem - No airflow to the sleeping area AND living 
area registers

Turn system off immediately. Both dampers may be wired 
backwards at the subbase or at the damper actuator (closing 
rather than opening).

Problem - No airflow to the sleeping area OR living 
area registers

Turn system off. One of the dampers may be wired backwards 
at the subbase or at the damper actuator (closing rather 
than opening).

Problem - When directing airflow to the sleeping area, the 
airflow is actually directed to the living area, and when 
directing the airflow to the living area, the airflow is actually 
directed to the sleeping area.

Turn system off. Check if the dampers are switched (sleeping 
area damper is wired to the living area terminals and the 
living area damper is wired to the sleeping area terminals.)

SENSOR INSTALLATION

Problem - nS message on thermostat.

Check that the sensor is wired correctly. Check for a short in
the sensor wiring.

Problem - Sleeping area temperature reading very high or 
very low.

Check that the correct sensor(s) have been used. One TS51
sensor is used in a single sensor installation. Two TS52 
sensors are used in a dual sensor installation.

COMFORT CONCERNS

Problem - Downstairs bedroom is too cold or too hot at night.

The Nighttime Airflow Control option directs more airflow to the
sleeping area and less airflow to the unoccupied living area. If 
the downstairs bedroom is on the same HVAC trunk as the 
living area, the downstairs bedroom may become uncomfortable
at night. Turn off the Nighttime Airflow Control option using the 
User Options.

Problem - The room temperature on the thermostat seems 
too high or too low.

The thermostat is factory calibrated within 1 degree. 
However, if a homeowner finds the temperature “feels” 
too high or too low, the thermostat can be calibrated to 
what the homeowner feels is the correct temperature using
Installer option 13 for the living area and option 14 for 
the sleeping area.

page 15 of 16

P/N 780101703 3/18 Rev A

Содержание EvenAir T21

Страница 1: ...OW to the sleeping and living areas in a home and provides remote access to your HVAC system using a smart phone tablet or PC The thermostat is installed in the downstairs living area a temperature se...

Страница 2: ...es on 24VAC from the HVAC equipment using the R and C wires Connects to the home WiFi network to provide remote access via the internet using smart phone tablet or PC FEATURES The airflow to the livin...

Страница 3: ...control feature This features allows the homeowner to change the airflow level as desired and hold that level indefinitely This feature needs to be enabled using Installer Option 18 The homeowner then...

Страница 4: ...Hold Vacant Changing the Setpoint Temperature The UP DOWN keys are used to change the setpoint temperature Tu Day Airflow Schedule MENU MODE Cool Set To AM Living Living Sleeping 5 Tu Day Airflow Sch...

Страница 5: ...ng User Option 1 to change the Night Schedule Start Time Default airflow level upstairs is 130 If a different airflow level is desired use User Option 4 to change the airflow level in heating and User...

Страница 6: ...s a User Option Nighttime Airflow Control Set the Nighttime Airflow in Heating will only show if Nighttime Airflow Control is ON Set the Nighttime Airflow in Cooling will only show if Nighttime Airflo...

Страница 7: ...anual before installing EvenAir products When servicing EvenAir system or accessing products turn off all power to these items R C WOB EQUIPMENT Y G TS COM COM CLS CLS OPN OPN Sleeping Living W2E Y2 T...

Страница 8: ...a the damper may be wired in parallel LEDs on the damper actuator indicate when the damper is fully open green or fully closed red When properly installed the dampers will never fully close Gas Electr...

Страница 9: ...nted circuit board and hand tighten screw The TS5 sensor can be installed in a single gang box or directly to the wall using the hardware provided HAND TIGHTEN Printed circuit board Brass washer Use 2...

Страница 10: ...4 Heating Stages Htg 0 1 or 2 1 Only displayed if HP selected in Option 1 14 15 16 17 18 19 21 20 22 23 Night Level LCD Backlight Airflow Control On or Off Enable User Airflow Control Up Stage Time Ma...

Страница 11: ...s used to display the next option The ENTER key is used to save options and return to normal thermostat operation The hidden BACK key is used to return to previous options and is located to the left o...

Страница 12: ...tomatic airflow control on or off If off the dampers fully open nighttime airflow options are disabled and airflow is no longer displayed on the thermostat 17 Airflow Control On or Off Factory Default...

Страница 13: ...ing Living Airflow Test Airflow Test NEXT NEXT Sleeping Living FAN ENTER FAN ENTER 03 04 Testing Heating Airflow Limits In TEST 3 the system is Off Touch to go to TEST 4 to activate heating Verify the...

Страница 14: ...ure sensor s Check for open wires or shortages ENTER AM Touch the UP DOWN keys to change the HOUR Touch NEXT CHANGE THE HOUR Touch the UP DOWN keys to change the MINUTE Touch NEXT CHANGE THE MINUTE To...

Страница 15: ...ting airflow to the sleeping area the airflow is actually directed to the living area and when directing the airflow to the living area the airflow is actually directed to the sleeping area Turn syste...

Страница 16: ...rols product visit www fieldcontrols com Field Controls Technical Support 1 800 742 8368 fieldtec fieldcontrols com Phone 252 522 3031 Fax 252 522 0214 www fieldcontrols com Field Controls LLC c Field...