Field Controls EvenAir T21 Скачать руководство пользователя страница 12

Use the 

 

keys to select the 
maximum allowable 
airflow in heating to 
the sleeping area. 

UP/DOWN

Use the 

 

keys to set the time at 
which second stage 
heating or cooling is 
activated. 

UP/DOWN

Sleeping

Airflow %

Option

Option

Heat

For options 20 - 23, use the installer test 
o

imum allowable airflow.

n the following page to determine the 

max

20  Maximum Airflow in Heating to Sleeping Area

19  Upstaging Time

Factory Default: 150%.   Range: 100% to 160%.

Factory Default: 10 min. Range: 5 to 30 min.

NEXT

ENTER

NEXT

ENTER

Touch NEXT or ENTER.

Touch NEXT or ENTER.

Use the 

 

keys to select the 
maximum allowable 
airflow in cooling to 
the sleeping area. 

UP/DOWN

Sleeping

Airflow %

Option

Cool

21  Maximum Airflow in Cooling to the Sleeping Area

Factory Default: 140%.   Range: 100% to 160%.

NEXT

ENTER

Touch NEXT or ENTER.

Use the 

 

keys to select the 
maximum allowable 
airflow in heating to 
the living area.

UP/DOWN

Living

Airflow %

Option

Heat

22  Maximum Airflow in Heating to the Living Area

Factory Default: 150%.   Range: 100% to 160%.

NEXT

ENTER

Touch NEXT or ENTER.

Use the 

 

keys to select the 
maximum allowable 
airflow in cooling to 
the living area.

UP/DOWN

Living

Airflow %

Option

Cool

23  Maximum Airflow in Cooling to the Living Area

Factory Default: 140%.   Range: 100% to 160%.

NEXT

ENTER

Touch NEXT or ENTER.

Use the 

 

keys to set the time 
in minutes to update 
the sleeping and 
living area airflow.

UP/DOWN

Option

This is the frequency, in minutes, that the damper 
position is updated.

15  Airflow Update Time

Factory Default: 2 Min. Range: 1 to 20 Min.

NEXT

ENTER

Touch NEXT or ENTER.

Option

Night

Use the 

key to 

turn the low level

UP 

 

The LCD has a low 
level backlight that 
can be used as a 
night light.

16  Night Level LCD Backlight

Factory Default: On. Range: On or Off.

NEXT

ENTER

backlight ON or touch the 

 key to turn 

OFF.  

DOWN

Use the 

 key to 

select ON for airflow 
control or touch the 

 key to select 

OFF to disable 
airflow control. 

UP

DOWN

Sleeping

Living

Airflow %

Option

This option turns the automatic airflow control on 
or off. If off, the dampers fully open, nighttime 
airflow options are disabled and airflow is no 
longer displayed on the thermostat.

17  Airflow Control, On or Off

Factory Default: On. Range: On or Off.

NEXT

ENTER

If Airflow Control was off and is now being turned on, 
the Nighttime Airflow option can be turned on using the 
User Options.

Touch NEXT or ENTER.

Use the 

 key to 

select ON to enable 
the user to turn off 
automatic airflow 
control in the user 
options.

UP

Homeowners with an unusual work schedule, 
home office, etc. may want to use this option. 
When turned On, this option enables the user to 
turn off automatic airflow control in the User 
Options. Airflow is adjusted by the homeowner. 
Nighttime Airflow option is still enabled but can 
be turned off using the User Options.

Option

18  Enable USER Airflow Control

Factory Default: Off. Range: On or Off.

NEXT

ENTER

Touch NEXT or ENTER.

Use the UP/DOWN 
keys to change the 
Living area 
temperature to the 
temperature that the 
user feels is correct. 

Living

Option

13  Calibrate Living Area Temperature Sensor

Factory Default: None.

Use the UP/DOWN 
keys to change the 
Sleeping area 
temperature to the 
temperature that the 
user feels is correct.

Sleeping

Option

14  Calibrate Sleeping Area Temperature Sensor

NEXT

ENTER

o

Range - +/-5

NEXT

ENTER

Factory Default: None.

o

Range - +/-5

Touch NEXT or ENTER.

Touch NEXT or ENTER.

Touch NEXT or ENTER.

Use the 

 

keys to select the 
maximum allowable 
temperature 
difference between 
the sleeping and 
living area.

UP/DOWN

Option

This is the maximum allowable temperature 
difference between the sleeping and living area 
temperatures. When the temperature difference is 
equal to or greater than the allowed differential, 
the airflow is adjusted.

24  Maximum Temperature Differential

o

Factory Default: 2 F. 

Range: 0  to 10 F

25  Factory Restore

NEXT

To restore factory 
settings, touch the 

 key to display 

YES then touch 
ENTER. 

UP

Option

WARNING! Factory Restore resets ALL settings.

NEXT

Option

NEXT

ENTER

ENTER

Touch NEXT or ENTER.

ENTER

To exit this option, 
touch 

 or 

NEXT

ENTER, or the hidden 
Back key.

INSTALLER SECTION

page 12 of 16

P/N 780101703 3/18 Rev A

Содержание EvenAir T21

Страница 1: ...OW to the sleeping and living areas in a home and provides remote access to your HVAC system using a smart phone tablet or PC The thermostat is installed in the downstairs living area a temperature se...

Страница 2: ...es on 24VAC from the HVAC equipment using the R and C wires Connects to the home WiFi network to provide remote access via the internet using smart phone tablet or PC FEATURES The airflow to the livin...

Страница 3: ...control feature This features allows the homeowner to change the airflow level as desired and hold that level indefinitely This feature needs to be enabled using Installer Option 18 The homeowner then...

Страница 4: ...Hold Vacant Changing the Setpoint Temperature The UP DOWN keys are used to change the setpoint temperature Tu Day Airflow Schedule MENU MODE Cool Set To AM Living Living Sleeping 5 Tu Day Airflow Sch...

Страница 5: ...ng User Option 1 to change the Night Schedule Start Time Default airflow level upstairs is 130 If a different airflow level is desired use User Option 4 to change the airflow level in heating and User...

Страница 6: ...s a User Option Nighttime Airflow Control Set the Nighttime Airflow in Heating will only show if Nighttime Airflow Control is ON Set the Nighttime Airflow in Cooling will only show if Nighttime Airflo...

Страница 7: ...anual before installing EvenAir products When servicing EvenAir system or accessing products turn off all power to these items R C WOB EQUIPMENT Y G TS COM COM CLS CLS OPN OPN Sleeping Living W2E Y2 T...

Страница 8: ...a the damper may be wired in parallel LEDs on the damper actuator indicate when the damper is fully open green or fully closed red When properly installed the dampers will never fully close Gas Electr...

Страница 9: ...nted circuit board and hand tighten screw The TS5 sensor can be installed in a single gang box or directly to the wall using the hardware provided HAND TIGHTEN Printed circuit board Brass washer Use 2...

Страница 10: ...4 Heating Stages Htg 0 1 or 2 1 Only displayed if HP selected in Option 1 14 15 16 17 18 19 21 20 22 23 Night Level LCD Backlight Airflow Control On or Off Enable User Airflow Control Up Stage Time Ma...

Страница 11: ...s used to display the next option The ENTER key is used to save options and return to normal thermostat operation The hidden BACK key is used to return to previous options and is located to the left o...

Страница 12: ...tomatic airflow control on or off If off the dampers fully open nighttime airflow options are disabled and airflow is no longer displayed on the thermostat 17 Airflow Control On or Off Factory Default...

Страница 13: ...ing Living Airflow Test Airflow Test NEXT NEXT Sleeping Living FAN ENTER FAN ENTER 03 04 Testing Heating Airflow Limits In TEST 3 the system is Off Touch to go to TEST 4 to activate heating Verify the...

Страница 14: ...ure sensor s Check for open wires or shortages ENTER AM Touch the UP DOWN keys to change the HOUR Touch NEXT CHANGE THE HOUR Touch the UP DOWN keys to change the MINUTE Touch NEXT CHANGE THE MINUTE To...

Страница 15: ...ting airflow to the sleeping area the airflow is actually directed to the living area and when directing the airflow to the living area the airflow is actually directed to the sleeping area Turn syste...

Страница 16: ...rols product visit www fieldcontrols com Field Controls Technical Support 1 800 742 8368 fieldtec fieldcontrols com Phone 252 522 3031 Fax 252 522 0214 www fieldcontrols com Field Controls LLC c Field...