![Field Controls EvenAir T21 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/field-controls/evenair-t21/evenair-t21_installation-and-user-manual_2287446011.webp)
Use the UP key to
select ON to turn on
smart recovery or
the DOWN key to
select OF to turn
smart recovery off.
Smart recovery initiates a heating or cooling call
so that the space is at temperature when the
setback period ends.
Option
Use the UP/DOWN
keys to select the
heating temperature
when the space is
vacant.
Option
Use the
keys to select the
cooling temperature
when the space is
vacant.
UP/DOWN
Option
Cool
Vacant
Vacant
Heat
12 Vacant Cooling Setpoint
11 Vacant Heating Setpoint
o
o
Range: 44 F to 75 F
o
Factory Default: 65 F.
10 Smart Recovery
Factory Default: Off. Range: On or Off.
Use the UP/DOWN
keys to change the
minimum off time
(minutes) before
restarting the
compressor.
Option
Option
Use the UP/DOWN
keys to change the
minimum off time
(minutes) before
restarting a gas
furnace or electric
strip heater.
06 Compressor Minimum Off Time
Factory Default: 2 Min. Range: 0 to 9 Min.
07 Heating Minimum Off Time
Factory Default: 0 Min. Range: 0 to 9 Min.
NEXT
ENTER
NEXT
ENTER
NEXT
ENTER
NEXT
ENTER
NEXT
ENTER
o
o
Range: 74 F to 95 F
o
Factory Default: 80 F.
Option
Use the UP key to
select “EL” for electric
operation where the
thermostat activates
the indoor fan (G
terminal) during
05 Setting the Fan Operation
Factory Default: Gas. Range: GA or EL
(Only displayed if Gas/Electric equipment,
GE, is selected in Option 01)
Touch NEXT or ENTER.
NEXT
ENTER
heating calls or DOWN key to select GA for gas
operation where the equipment plenum sensor
activates the indoor fan in heating calls.
Touch NEXT or ENTER.
Touch NEXT or ENTER.
Touch NEXT or ENTER.
Touch NEXT or ENTER.
Touch NEXT or ENTER.
ACCESSING INSTALLER OPTIONS
!
Press the touchscreen with your fingertip
only, using a firm touch. Do not use a sharp
object such as a pen or pencil.
!
The NEXT key is used to display the next
option.
!
The ENTER key is used to save options and
return to normal thermostat operation.
!
The hidden BACK key is used to return to
previous options and is located to the left of
the NEXT key.
To access the Installer Options,
and
the hidden Enter key for 7 seconds until
the first Option appears on the screen.
TOUCH
HOLD
Living
Tu
Day
Sleeping
Living
Airflow %
COOL
Schedule
AUTO
FAN
MENU
Cool
Set To
SYSTEM
AM
TOUCH
HOLD
and
this key
for 7 seconds to access the
Installer Options.
The hidden BACK
key can be used to
return to previous
options.
MODE
Use the UP/DOWN
keys to select
Option
01 Selecting the Equipment Type
This option is used
to select gas/electric
or heat pump
equipment.
Option
Use the UP/DOWN
keys to select o for
This option is used
to select an O or B
type reversing valve.
Factory Default: GE. Range: GE or HP
02 Reversing Valve
Factory Default: O. Range: o or b
(Only displayed if Heat Pump equipment,
HP is selected in Option 01)
NEXT
NEXT
ENTER
gas/electric (GE) or heat pump (HP).
Touch NEXT or ENTER.
O-Type or b for B-Type.
Touch NEXT or ENTER.
Use the UP/DOWN
keys to set 0 or 1
stage.
Touch NEXT or
ENTER.
Option
03 Setting the Compressor Stages
This option is used to set the number of
compressor stages.
Factory Default: 1 . Range: 0 or 1
NEXT
ENTER
Option
Use the UP/DOWN
keys to set 0, 1 or 2
stage.
Touch NEXT or
ENTER.
Factory Default: 1 Stage. Range: 0, 1 or 2
04 Setting the Heating Stages
NEXT
ENTER
Use the UP/DOWN
keys to select 0, 1,
2.
Touch NEXT or
ENTER.
Option
Differential Mode0
Differential Mode1
Differential Mode2
o
1.0 On/Off Span.
o
1.5 On/Off Span.
o
2.0 On/Off Span.
09 Setting On-Off Temp Differential
Factory Default: #1. Range: 0, 1 or 2.
Option
Use the UP/DOWN
keys to change the
minimum run time
(minutes) before
turning a system off.
08 Minimum Run Time
Factory Default: 2 Min. Range: 0 to 9 Min.
NEXT
ENTER
NEXT
ENTER
Touch NEXT or ENTER.
INSTALLER SECTION
page 11 of 16
P/N 780101703 3/18 Rev A
ENTER