Software Functional Overview
3-40
FIC A360 Service Manual
Register
Bit Number
Function Address
Name
R/W
7 6 5 4 3 2 1 0
Logic Default Description
1Ah
*3
Battery
State
R(/W)
DATA[15:3] *1
All bits are 0
C
R
I
T
C
H
G
D
C
H
G
- -
DCHG=1:
CHG =1 :
CRIT =1 :
The battery is
discharged
The battery is
charged
The battery is critical
(Empty)
1Ch
*3
Battery
Present
rate
R(/W) DATA[15:0]
*1
-
0xffff
0x0000-0xfffe(mW)
0xffff: Unknown
1Eh
*3
Battery
Remaining
Capacity
R(/W) DATA[15:0]
*1
-
0xffff
0x0000-0xfffe(mWh)
0xffff: Unknown
1
st
Battery
[ _BST ]
20h
*3
Battery
present
Voltage
R(/W) DATA[15:0]
*1
-
0xffff
0x0000-0xfffe(mV)
0xffff: Unknown
1
st
Battery
[ _BTP ]
22h
Battery
Trip Point
R/W DATA[15:0]
*1 -
0x000
0
0x0000 :Clear the trip point
0x0001-0xffff(mWh)
2
nd
Battery
[ _BIF ]
24h to
3Ch *3
*2 *2
*2
*2
*2
*2
2
nd
Battery
[ _BST ]
3Eh to
44h *3
*2 *2
*2
*2
*2
*2
2
nd
Battery
[ _BTP ]
46h *2 *2
*2
*2
*2
*2
-
48h
Battery
data
Size
R(/W)
DATA[7:0]
-
-
0x01 : DATA size is
3byte.(PMU06A)
0x00 :DATA size is 2 byte.
(PMU06) *8
49h
Design
capacity
R(/W)
DATA[23:16] *1 *7
-
0xff
PMU06A use this data with
02/03h. *7 *8
1
st
Battery
[_BIF]
4Ah
Last Full
Charge
Capacity
R(/W)
DATA[23:16] *1 *7
-
0xff
PMU06A use this data with
04/05h. *7 *8
1
st
Battery
[_BST]
4Bh
Battery
Remaining
Capacity
R(/W)
DATA[23:16] *1 *7
-
0xff
PMU06A use this data with
1E/1Fh. *7 *8
1
st
Battery
[_BTP]
4Ch
Battery
Trip
Point
R(/W)
DATA[23:16] *1 *7
-
0x00
PMU06A use this data with
22/23h. *7 *8
4Dh
Design
capacity
R(/W)
DATA[23:16] *1 *7
-
0xff
PMU06A use this data with
26/27h. *7 *8
2
nd
Battery
[_BIF]
4Eh
Last Full
Charge
Capacity
R/(/W)
DATA[23:16] *1 *7
-
0xff
PMU06A use this data with
28/29h. *7 *8
2
nd
Battery
[_BST]
4Fh
Battery
Remaing
Capacity
R(/W)
DATA[23:16] *1 *7
-
0xff
PMU06A use this data with
42/43h. *7 *8
2
nd
Battery
[_BTP]
50h
Battery
Trip
Point
R(/W)
DATA[23:16] *1 *7
0x00
PMU06A use this data with
46/47h. *7 *8
51h to
6Bh *3
Reserved
R/W
Don’t care
-
-
*1:
The register type is word.
*2:
Same as 1
st
Battery CMBatt Data.
*3:
This register is not cleared if the system is in S4-S5 state.
R(/W): This is the read only register, but the written data will be able to read back till PMU
updates the data periodically, or PMU detects the status change.
Содержание A360 Reference and