Software Functional Overview
FIC A360 Service Manual
3-45
Register
Bit Number
Function Address
Name
R/W
7 6 5 4 3 2 1 0
Logic
Default Description
D0h
BAT_CHG
_CONT
R/W RES[7:5]
C
H
G
_
R
D
Y
#
RES
[3:2]
C
H
G
2
C
H
G
1
- -
CHG_RDY#
=0 : Charge ready
CHGn
=1 : The nth battery is charged
D1h
BAT_DCH
_PRI
R/W RES[7:3]
PAT
[2:0]
- 0x00
Battery discharge priority
0 : 2 1
1 : 1 2
2 : 2 1
3 : 2 1
4 : 1 2
5 : 1 2
6 : Same as 0
7 : Simultaneously discharge
(Read only :This data can be
set using PMU register)
D2h
BAT_DCH
_CONT
R/W RES[7:2]
D
C
H
G
2
D
C
H
G
1
0: Not
discharge
1:
Discharge
-
The discharge battery can be
selected one of the batteries
can be discharged.
D3h
BAT_WAR
_ABS
R/W DATA[15:0]
*1
-
0x0000
Absolute capacity battery
Warning detection point
0x0000-0xffff (mWh)
D5h
BAT_LOW
_ABS
R/W DATA[15:0]
*1
-
0x0000
Absolute capacity battery Low
detection point
0x0000-0xffff (mWh)
D7h
BAT_WAR
_REL
R/W DATA
[7:0]
-
0x10
Relative capacity battery
Warning detection point
00-C8h (0-100% step 0.5%)
D8h
BAT_LOW
_REL
R/W DATA
[7:0]
-
0x06
Relative capacity battery Low
detection point
00-C8h (0-100% step 0.5%)
D9h
*3
FULL
_DATA
R/W DATA
[7:0]
-
0xbe
Full charge cancel point
00-C8h (0-100% step 0.5%)
Dah
CC_CUR_
DATA
R DATA
[7:0] -
0x00
Battery charging current
setting
0x01-0xff (0.02-5.10A step
0.02A)
0x00 Depends on the
battery
This register is “read only”, to
change the value, use the
register in PMU registers area.
DBh To
DCh
BTP2 R/W DATA
[15:0]
-
0x0000
0x0000: Clear the trip point
0x0001-0xffff : (mWh)
When all of the battery’s
capacities lesser than this
setting value, the BTP2 is
detected if event is enabled.
Battery
control
DDh To
DFh
Reserved R/W
Don't
care
-
-
*3:
This register is not cleared if the system is in S4-S5 state.
R(/W): This is the read only register, but the written data will be able to read back till PMU
updates the data periodically, or PMU detects the status change.