![Fibocom SC806 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/fibocom/sc806/sc806_hardware-user-manual_2286856030.webp)
The copyright of this document is owned by Fibocom Wireless Inc., and the document shall not be replicated without approval.
SC806Hardware User ManualPage30 of 70
VDD_SD_L11
1.75~3.337
2.95
600
VDD_USIM1_L14
1.75~3.337
1.8/2.95
55
VDD_ USIM2_L15
1.75~3.337
1.8/2.95
55
3.3
Control Signal
The SC806 uses one control signal to startup/shutdown, restart, and sleep/wakeup the module.
Table9startup/shutdown pin definition
3.3.1
Module Startup
After VBAT is powered on, the module can be turned on by setting the KEY_ON/OFF signal low for more
than 2 seconds. The KEY_ON/OFF control reference diagram is as follows:
Figure 6Button Startup Circuit
Pin No.
Pin name
I/O
Description
Note
114
KEY_ON/OFF
DI
The default is high, and low is effective.
This pin can be used to startup/shutdown,
restart, and sleep/wakeup the module