background image

Warranty, Service and Terms and Conditions of Sale 

For information about Warranty or Service information, please see our published ‘Terms and Conditions of 

Sale’. This document is available o

fiberplex.com 

 or can be obtained by requesting it from 

[email protected]

 or calling 301.604.0100. 

Disposal 

Disposal of Packing Materials  

The packing materials have been selected with environmental and disposal issues in mind. All packing material 

can be recycled. Recycling packing saves raw materials and reduces the volume of waste. If you need to 

dispose of the transport packing materials, recycling is encouraged. 

Disposal of Used Equipment  

Used equipment contains valuable raw materials as well as substances that must be disposed of 

professionally. Please dispose of used equipment via an authorized specialist dealer or via the public waste 

disposal system, ensuring any material that can be recycled has been. Please take care that your used 

equipment cannot be abused. After having disconnected your used equipment from the mains supply, make 

sure that the mains connector and the mains cable are made useless. 

Disclaimer 

The information in this document has been carefully checked and is believed to be accurate at the time of 

publication. However, no liability is assumed by FiberPlex for inaccuracies, errors, or omissions, nor for loss or 

damage resulting either directly or indirectly from use of the information contained herein.

  

Notice 

The firmware included in this product utilizes the Atmel Software Framework (ASF), Copyright (c) 2011 - 2012 Atmel Corporation. All rights 

reserved. 
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 
1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 
2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the 

documentation and/or other materials provided with the distribution. 
3. The name of Atmel may not be used to endorse or promote products derived from this software without specific prior written permission. 
4. This software may only be redistributed and used in connection with an Atmel micro-controller product. 
THIS SOFTWARE IS PROVIDED BY ATMEL “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED 

WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NON-INFRINGEMENT ARE EXPRESSLY AND SPECIFICALLY 

DISCLAIMED. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES 

(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS 

INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING 

NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. 

 

Содержание FOI-6010

Страница 1: ...USER MANUAL Flexible Interface SFP SFP Transceiver Workbox FOI 6010 TD 6010...

Страница 2: ......

Страница 3: ...rformed by trained personnel in accordance with the applicable regulations Installation Site Install the unit in a place where the following conditions are met The temperature and the relative humidit...

Страница 4: ...nformation contained herein Notice The firmware included in this product utilizes the Atmel Software Framework ASF Copyright c 2011 2012 Atmel Corporation All rights reserved Redistribution and use in...

Страница 5: ...d streams together so that the different interface protocols can talk the same language Since the fiber based SFPs are the most generic it is usually possible to connect not only two different copper...

Страница 6: ...should be retained until the shipment has been checked for completeness and the equipment has been checked mechanically and electrically If the shipment is incomplete if there is mechanical damage or...

Страница 7: ...lent to SFP Port A Any SFP installed in this slot will be directly electrically connected to the SFP in Port A Any signals presented in the Receive of Port A will exit on the Transmit of Port B and vi...

Страница 8: ...its or internal failure Rear Indicators Connections Figure 2 TD 6010 left and FOI 6010 right Rear Face Circular DC Power Connection DC power entry for the unit On the FOI 6010 this is a Lemo connector...

Страница 9: ...can accommodate hot swapped redundant power Alternately the FOI 6010 can be used in a standalone application when paired with a PSQ 4909 for full range AC operation or the PSQ 4920 for 12 48VDC operat...

Страница 10: ...dule that you use to disengage the module from a port Handling Warnings SFP Modules are static sensitive To prevent damage from electrostatic discharge ESD it is recommended to attach an ESD preventat...

Страница 11: ...he bail clasp on the SFP Module with your finger in a downward direction Actuator Button Gently press the actuator up or in while pulling the body of the SFP Module to release the SFP Module from the...

Страница 12: ...SMPTE for broadcast quality digital video transmission Other standards evolved from this original standard defining Enhanced High definition HD 3G SDI 1080p and Ultra High definition UHD or 4K video 2...

Страница 13: ...of the internal serial communication pins were reassigned The FOI TD 6010 will accept any of these pinout schemes in any combination For example you can have an MSA compliant SFP in the A position an...

Страница 14: ...Specifications Figure 7 FOI 6010 Dimensions 1 45 36 9 2 56 65 1 13 3 2 4 50 114 3 42 10 6 11 2 9...

Страница 15: ...ice External SFP Interfaces Min Typ Max unit Data Rate 155 12 500 Mb Recommended Jitter 40 Psec Operating Voltage 3 3 VDC Maximum Current 500 mA Optical Modules 2 SFP MSA SFF 8431 SFF 8432 SFF 8433 co...

Страница 16: ...18040 412 Guilford Rd Annapolis Junction MD 20701 fiberplex com clients fiberplex com 301 604 0100 6010UM 1607...