uFAC

 – USB 2.0 Micro-B connector for configuration and monitoring of SFP registers. This functionality is 

not currently supported. 

 

Status

 – LED which indicates the health status of the unit. The LED can be interpreted according to the 

following table. 
 

Status Indicator 

Off 

If Power LED is on, there is an internal failure inside the FOI. Replace 

Green 

Power supply is operating properly 

Amber 

At limit of normal range of temperature, apply more cooling to the unit 

Red 

Exceeding temperature limits or internal failure 

 

Rear Indicators/Connections 

 

Figure 2 TD-6010 (left) and FOI-6010 (right) Rear Face 

 

Circular DC Power Connection

 – DC power entry for the unit. On the FOI-6010 this is a Lemo connector 

designed to interface with either a PSQ power module or RMC chassis. On the TD-6010 this is a standard DC 

connection for use with the included DC wall power supply. 

 

Phoenix CD Power Connection

 – Secondary power option for the TD-6010. This is wired in direct parallel 

with the Circular connector and has the addition of a positive earth chassis ground connection. This can be 

used to power the unit on a client supplied power buss.  
 
 

 

Figure 3 FOI-6010 Installed in an RMC-3101 Chassis 

 

 

8

8

9

Содержание FOI-6010

Страница 1: ...USER MANUAL Flexible Interface SFP SFP Transceiver Workbox FOI 6010 TD 6010...

Страница 2: ......

Страница 3: ...rformed by trained personnel in accordance with the applicable regulations Installation Site Install the unit in a place where the following conditions are met The temperature and the relative humidit...

Страница 4: ...nformation contained herein Notice The firmware included in this product utilizes the Atmel Software Framework ASF Copyright c 2011 2012 Atmel Corporation All rights reserved Redistribution and use in...

Страница 5: ...d streams together so that the different interface protocols can talk the same language Since the fiber based SFPs are the most generic it is usually possible to connect not only two different copper...

Страница 6: ...should be retained until the shipment has been checked for completeness and the equipment has been checked mechanically and electrically If the shipment is incomplete if there is mechanical damage or...

Страница 7: ...lent to SFP Port A Any SFP installed in this slot will be directly electrically connected to the SFP in Port A Any signals presented in the Receive of Port A will exit on the Transmit of Port B and vi...

Страница 8: ...its or internal failure Rear Indicators Connections Figure 2 TD 6010 left and FOI 6010 right Rear Face Circular DC Power Connection DC power entry for the unit On the FOI 6010 this is a Lemo connector...

Страница 9: ...can accommodate hot swapped redundant power Alternately the FOI 6010 can be used in a standalone application when paired with a PSQ 4909 for full range AC operation or the PSQ 4920 for 12 48VDC operat...

Страница 10: ...dule that you use to disengage the module from a port Handling Warnings SFP Modules are static sensitive To prevent damage from electrostatic discharge ESD it is recommended to attach an ESD preventat...

Страница 11: ...he bail clasp on the SFP Module with your finger in a downward direction Actuator Button Gently press the actuator up or in while pulling the body of the SFP Module to release the SFP Module from the...

Страница 12: ...SMPTE for broadcast quality digital video transmission Other standards evolved from this original standard defining Enhanced High definition HD 3G SDI 1080p and Ultra High definition UHD or 4K video 2...

Страница 13: ...of the internal serial communication pins were reassigned The FOI TD 6010 will accept any of these pinout schemes in any combination For example you can have an MSA compliant SFP in the A position an...

Страница 14: ...Specifications Figure 7 FOI 6010 Dimensions 1 45 36 9 2 56 65 1 13 3 2 4 50 114 3 42 10 6 11 2 9...

Страница 15: ...ice External SFP Interfaces Min Typ Max unit Data Rate 155 12 500 Mb Recommended Jitter 40 Psec Operating Voltage 3 3 VDC Maximum Current 500 mA Optical Modules 2 SFP MSA SFF 8431 SFF 8432 SFF 8433 co...

Страница 16: ...18040 412 Guilford Rd Annapolis Junction MD 20701 fiberplex com clients fiberplex com 301 604 0100 6010UM 1607...

Отзывы: