Service loops
Service loops provide extra sensor cable for making future repairs, and for making fusion splices.
A 10 m (33 ft.) service loop is recommended for every 300 m (984 ft.) of installed sensor cable. A
10 m service loop is also recommended on the hinged side of each gate that is protected by
sensor cable. In addition, a 10 m (33 ft.) splice point service loop is required for each section of
sensor cable at all splice enclosure locations. A 10 m service loop is typically comprised of 5
circular loops of cable with a 60 cm (2 ft.) diameter (see
).
Isolation loops
Isolation loops are optional, but are recommended for situations where a zone needs to be
isolated from adjacent zones (e.g., gate isolation). Isolation loops are also recommended as a
buffer between detecting sensor cable and software defined non-detecting cable. Fence-mounted
isolation loops use 14 in. steel cable ties to secure 7 loops of sensor cable to the fence. The 7
loops have a 60 cm (2 ft.) diameter, which requires approximately 13 m of sensor cable (see
).
Buried vault
Another method for zone to zone isolation is to move the sensor cable off the fence through
conduit and then form a 13 m (43 ft.) isolation loop inside a buried vault. The cable is then run
through another section of conduit and back onto the fence where it continues as another zone.
provides the dimensions for the FiberPatrol buried vault.
Figure 9 Buried vault dimensions
46 cm
69 cm
(27 in.)
(18 in.)
49.5 cm
(19.5 in.)
82 cm
(32.25 in.)
103 cm
(40.5 in.)
top view
end view
side view
NOTE: dig hole 51 cm (20 in.) D X 76 cm (30 in.) W X 107 cm (42 in.) L