6 Cables
Connection Method
Table 6-7 describes how the subrack power cable is connected.
Table 6-7
Connection Method of the Subrack Power Cable
Cable Name
Terminal
Connected to
Subrack power
cable
Blue wire
Any branch switch on the PDP
Blue wire
0 V terminal of the XS2/XS5 on the PDP
Connector post
Power supply jack on the PWRS1 card
Technical Parameters
Table 6-8 lists technical parameters of the subrack power cable.
Table 6-8
Technical Parameters of the Subrack Power Cable
Item
Specification
Power terminal
2.5mm
2
/27A/blue
Connector post
12A/4P
Power cable (blue, black)
RVV2 2.5 (49/0.25)
6.2.4
Subrack Protection Earth Ground Cable
The following introduces the model, usage, structure, connection method, and
technical parameters of the subrack protection earth ground cable.
Model
The model of the subrack protection earth ground cable is 3.696.084.
Usage
The subrack protection earth ground cable connects a subrack to the vertical
mounting flange of the cabinet to implement earth ground protection of the subrack.
Version: A
6-7