30.08.2019
manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGWDEU-111
manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGWDEU-111
8/15
Setting
Description
0
LED disabled
1
White
2
Red
3
Green
4
Blue
5
Yellow
6
Cyan
7
Magenta
8
colour changes smoothly depending on measured power
9
colour changes in steps depending on measured power
Parameter 12: LED framecolour when OFF
This parameter defines the LED colour when the device is OFF.
Size: 1 Byte, Default Value: 0
Setting
Description
0
LED disabled
1
White
2
Red
3
Green
4
Blue
5
Yellow
6
Cyan
7
Magenta
Parameter 13: LED framebrightness
This parameter allows to adjust the LED frame brightness.
Size: 1 Byte, Default Value: 100
Setting
Description
0
LED disabled
1 - 100
(1-100% brightness)
101
brightness directly proportional to set level
102
brightness inversely proportional to set level
Parameter 24: Buttons orientation
This parameter allows reversing the operation of the buttons.
Size: 1 Byte, Default Value: 0
Setting
Description
0
default (1st button brightens, 2nd button dims)
1
reversed (1st button dims, 2nd button brightens)
Parameter 30: Alarm configuration - 1st slot
This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set
according to the official Z-Wave protocol specification.
Size: 4 Byte, Default Value: 0
Setting
Description
1 - 0
[MSB]Notification Type
2
Notification Value
3
Event/State Parameters
4
[LSB]action
Parameter 31: Alarm configuration - 2nd slot
This parameter determines to which alarm frames and how the device should react. The parameters consist of 4 bytes, three most significant bytes are set
according to the official Z-Wave protocol specification.