Parameter 41: Second buttonscenes sent
This parameter determines which actions result in sending scene IDs assigned to them. Values can be combined (e.g. 1+2=3 means that scenes for single and
double click are sent). Enabling scenes for triple click disables entering the device in learn mode by triple clicking.
Size: 1 Byte, Default Value: 0
Setting
Description
1
Key pressed 1 time
2
Key pressed 2 time
4
Key pressed 3 time
8
Key hold down and key released
Parameter 60: Power reportsinclude self-consumption
This parameter determines whether the power measurements should include power consumed by the device itself.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Self-consumption not included
1
Self-consumption included
Parameter 61: Power reportson change
This parameter defines minimal change (from the last reported) in measured power that results in sending new report. For loads under 50W the parameter is
irrelevant, report are sent every 5W change.
Size: 2 Byte, Default Value: 15
Setting
Description
0
reporting on change disabled
1 - 500
(1-500%, 1% step)minimal change
Parameter 62: Power reportsperiodic
This parameter defines reporting interval for measured power. Periodic reports are independent from changes in value (parameter 61).
Size: 2 Byte, Default Value: 3600
Setting
Description
0
periodic reports disabled
30 - 32400
(30s-9h, 1s step)time interval
Parameter 65: Energy reportson change
This parameter defines minimal change (from the last reported) in measured energy that results in sending new report.
Size: 2 Byte, Default Value: 10
Setting
Description
0
reporting on change disabled
1 - 500
(0.01-5kWh, 0.01kWh step)minimal change
Parameter 66: Energy reportsperiodic
This parameter defines reporting interval for measured energy. Periodic reports are independent from changes in value (parameter 65).
Size: 2 Byte, Default Value: 3600
Setting
Description
0
periodic reports disabled
30 - 32400
(30s-9h, 1s step)time interval
Parameter 150: Minimum brightness level
This parameter is set automatically during the calibration process, but can be changed manually after the calibration.
Size: 1 Byte, Default Value: 1
Setting
Description
1 - 98
(1-98%, 1% step)level of brightness
Parameter 151: Maximum brightness level
This parameter is set automatically during the calibration process, but can be changed manually after the calibration.
Size: 1 Byte, Default Value: 99
Setting
Description
2 - 99
(2-99%, 1% step)level of brightness