background image

30.08.2019

manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGWDEU-111

manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGWDEU-111

14/15

Setting

Description

0

measurement based on the standard algorithm

1

approximation based on the calibration data

2

approximation based on the control angle

Parameter 179: Approximated power at the maximum brightness level

This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level. 

Size: 2 Byte, Default Value: 0

Setting

Description

0 - 500

(0-500W, 1W step)power consumed by the load at the maximum brightness level.

Technical Data

Dimensions

0.0860000x0.0860000x0.0500000 mm

Weight

93 gr

Hardware Platform

ZM5101

EAN

5902701701369

IP Class

IP IP 20

Voltage

230 V

Load

1,3A

Device Type

Light Dimmer Switch

Network Operation

Always On Slave

Firmware Version

HW: 1 FW: 5.00:05.00:03.06

Z-Wave Version

6.81.01

Certification ID

ZC10-19046426

Z-Wave Product Id

0x010F.0x1C01.0x1000

Color

White

Switch Type

Push Button

Electric Load Type

FluorescentIncandescentLED

Supported Meter Type

Electric Energy

Supported Notification Types

Power ManagementSystem

Loads Controlled

4

Security V2

S2_UNAUTHENTICATED ,S2_AUTHENTICATED

Frequency

Europe - 868,4 Mhz

Maximum transmission power

5 mW

Supported Command Classes

Application Status

Association Grp Info V2

Association V2

Basic

Central Scene V3

Configuration

Crc 16 Encap

Device Reset Locally

Firmware Update Md V4

Manufacturer Specific V2

Содержание FIBEFGWDEU-111

Страница 1: ...This device is suited for use in the region mentioned in the Quickstart section Z Wave ensures a reliable communication by reconfirming every message two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter This device and every other certified Z Wave device can be used together w...

Страница 2: ...lease the button when the device glows yellow 3 Quickly click the button to confirm 4 After a few seconds the device will be restarted which is signaled with the red LED color Safety Warning for Mains Powered Devices ATTENTION only authorized technicians under consideration of the country specific installation guidelines norms may do works with mains power Prior to the assembly of the product the ...

Страница 3: ...on 1 3 wire installation 2 2 wire installation Assembling the device When installing the device in the mounting box orient the device with terminal screws going up or to the left for horizontal button position to ensure button order The light effect might look different for covers other than FIBARO Walli You can adjust color and or intensity of the LEDs to suit the particular cover using parameter...

Страница 4: ... button adapter to the device 4 Snap the new switch button to the device Legrand Cover 1 Insert the device with mounting frame into the mounting box and secure with mounting claws and screws 2 Snap the switch button adapter to the device 3 Snap the new inner cover plate to the device 4 Snap the new outer cover plate to the device 5 Snap the new switch button to the device Schneider Cover 1 Insert ...

Страница 5: ... the process is completed 4 The device can be added to the Z Wave network Calibration The device is equipped with an algorithm of smart light source detection It automatically selects suitable control mode leading edge for inductive loads trailing edge for capacitive or resistive loads and adjusts maximum and minimum light levels Installer is obliged to verify the proper operation of the device Th...

Страница 6: ...ARO Bypass 2 Green reset energy consumption memory Yellow reset to factory defaults Menu Menu allows to perform Z Wave network actions In order to use the menu 1 Quickly three times click then press and hold one of the buttons to enter the menu device blinks to signal adding status see Visual indications 2 Release the button when device signals desired position with colour BLUE start load calibrat...

Страница 7: ...ciated deviceson off reflecting button operation uses Basic command class 3 5 3rd association groupDimmer is used to change level of associateddevices reflecting button operation uses Switch Multilevel command class Configuration Parameters Z Wave products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further...

Страница 8: ...ctly proportional to set level 102 brightness inversely proportional to set level Parameter 24 Buttons orientation This parameter allows reversing the operation of the buttons Size 1 Byte Default Value 0 Setting Description 0 default 1st button brightens 2nd button dims 1 reversed 1st button dims 2nd button brightens Parameter 30 Alarm configuration 1st slot This parameter determines to which alar...

Страница 9: ...tatus 3 Event State Parameters 4 LSB action Parameter 34 Alarm configuration 5th slot This parameter determines to which alarm frames and how the device should react Theparameters consist of 4 bytes three most significant bytes are set according to the officialZ Wave protocol specification Size 4 Byte Default Value 0 Setting Description 1 MSB Notification Type 2 Notification Status 3 Event State P...

Страница 10: ...bled 1 500 1 500 1 step minimal change Parameter 62 Power reportsperiodic This parameter defines reporting interval for measured power Periodic reports are independent from changes in value parameter 61 Size 2 Byte Default Value 3600 Setting Description 0 periodic reports disabled 30 32400 30s 9h 1s step time interval Parameter 65 Energy reportson change This parameter defines minimal change from ...

Страница 11: ...automatic control Size 2 Byte Default Value 1 Setting Description 0 255 This parameter defines the time of performing a single dimming step set in parameter 154 during the automatic control Parameter 156 Manual controldimming step size This parameter defines the percentage value of the dimming step during the manual control Size 1 Byte Default Value 1 Setting Description 1 99 1 99 1 step dimming s...

Страница 12: ...equal to the current level 255 value sent Parameter 164 Second buttonSwitch OFF value sent to 2nd and 3rd association groups This parameter defines value sent with Switch OFF command to devices associated in 2nd and 3rd association group Size 2 Byte Default Value 0 Setting Description 0 99 value sent 254 send value equal to the current level Parameter 165 Double clickset level This parameter defin...

Страница 13: ...failure burnt out bulb if parameter 176 is set to 1 also after SURGE output overvoltage and OVERCURRENT output overcurrent 4 Auto calibration after each power on or after each LOAD ERROR no load load failure burnt out bulb if parameter 176 is set to 1 also after SURGE output overvoltage and OVERCURRENT output overcurrent Parameter 176 Behaviour after OVERCURRENT or SURGE Error occurrences related ...

Страница 14: ...sions 0 0860000x0 0860000x0 0500000 mm Weight 93 gr Hardware Platform ZM5101 EAN 5902701701369 IP Class IP IP 20 Voltage 230 V Load 1 3A Device Type Light Dimmer Switch Network Operation Always On Slave Firmware Version HW 1 FW 5 00 05 00 03 06 Z Wave Version 6 81 01 Certification ID ZC10 19046426 Z Wave Product Id 0x010F 0x1C01 0x1000 Color White Switch Type Push Button Electric Load Type Fluores...

Страница 15: ...ller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless...

Отзывы: