MAGENTA - start range test

YELLOW - reset the device

3. Quickly click the button to confirm.
 

Activating scenes

 

The device can activate scenes in the Z-Wave controller by sending scene ID and attribute of a specific action using Central Scene Command Class.

In order for this functionality to work connect the monostable or bistable switch to the IN1 or IN2 input and set parameter 20 (IN1) or 21 (IN2) to 2 or 3.

By default scenes are not activated, set parameters 40 and 41 to enable scene activation for selected actions.
 

 
 

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to
communicate with the device, a static controller 

C

 is needed in the network. This controller will maintain a mailbox for the battery operated devices and store

commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is
significantly decreased.

This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox.
Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this
controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the
device. To wakeup the device please perform the following action: FIBARO Smart Implant is powered using DC power supply unit so it is always awake.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

1. Make sure a device is in factory reset state before including. In doubt exclude before include.
2. If inclusion still fails, check if both devices use the same frequency.
3. Remove all dead devices from associations. Otherwise you will see severe delays.
4. Never use sleeping battery devices without a central controller.
5. Dont poll FLIRS devices.
6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are
always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will

Содержание FIBEFGBS-222

Страница 1: ...mation about Z Wave technology devices white papers etc please refer to www z wave info Product Description FIBARO Smart Implant allows to enhance the functionality of wired sensors and other devices by adding Z Wave network communication You can connect binary sensors analog sensors DS18B20 temperature sensors or DHT22 humidity and temperature sensor to report their readings to the Z Wave control...

Страница 2: ...ection with regular alarm line 1 alarm sensor 2 alarm system hub Example connection with parametric alarm line 1 alarm sensor 2 alarm system hub 3 Verify correctness of connection 4 Arrange the device and its antenna in the housing 5 Power the device 6 Add the device to the Z Wave network 7 Change values of parameters Connected to IN1 Normally close change parameter 20 to 0 Normally open change pa...

Страница 3: ...o the Z Wave network 6 Change values of parameters Connected to IN1 change parameter 20 to 4 Connected to IN2 change parameter 21 to 4 Connection with 2 wire 0 10V Sensor The 2 wire analog sensor requires pull up resistor You can connect up to 2 analog sensors to IN1 IN2 terminals The 12V supply is required for these type of sensors 1 Disconnect Power 2 Connect with the diagram below 3 Verify the ...

Страница 4: ...ry sensors to IN1 IN2 terminals 1 Disconnect Power 2 Connect with the diagram below 3 Verify the correctness of connection 4 Power the device 5 Add the device to the Z Wave network 6 Change values of parameters 6 1 Binary sensor Connected to IN1 Normally close change parameter 20 to 0 Normally open change parameter 20 to 1 Connected to IN2 Normally close change parameter 21 to 0 Normally open chan...

Страница 5: ...ht on the device Inclusion 1 Power the device 2 Set the main controller in Security non Security Mode add mode see the controllers manual 3 Quickly triple click button on the device housing or switch connected to IN1 or IN2 4 If you are adding in Security S2 Authenticated scan the DSK QR code or input the 5 digit PIN code label on the bottom of the box 5 LED will start blinking yellow wait for the...

Страница 6: ...ommunication with the main controller through other modules repeaters Visual indicator glowing yellow the device communicates with the main controller through the other modules After 2 seconds the device will retry to establish a direct communication with the main controller which will be signalled with visual indicator pulsing green Visual indicator pulsing violet the device does communicate at t...

Страница 7: ...ired wakeup interval and the node ID of the controller If the device was included by a static controller this controller will usually perform all necessary configurations The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device To wakeup the device please perform the following action FIBARO Smart Implant is powered using DC power supply unit so it...

Страница 8: ...ntral Scene 3 Bistable button Central Scene 4 Analog input without internal pull up Sensor Multilevel 5 Analog input with internal pullup Sensor Multilevel Parameter 21 Input 2 operating mode This parameter allows to choose mode of 2nd input Size 1 Byte Default Value 2 Setting Description 0 Normally closed alarm input Notification CC 1 Normally open alarm input Notification CC 2 Monostable button ...

Страница 9: ...Input 2 value sent to 3rd association group when activated This parameter defines value sent to devices in 3rd association group when IN2 input is triggered using Basic Command Class Size 2 Byte Default Value 255 Setting Description 0 255 value send to devices Parameter 54 Input 2 value sent to 3rd association group when deactivated This parameter defines value sent to devices in 2nd association g...

Страница 10: ... connected DS18B20 or DHT22 sensors Size 2 Byte Default Value 0 Setting Description 0 periodical reports disabled 60 32400 60s 9h Parameter 150 Input 1 sensitivity This parameter defines the inertia time of IN1 input in alarm modes Adjust this parameter to prevent bouncing or signal disruptions Parameter is relevant only if parameter 20 is set to 0 or 1 alarm mode Size 1 Byte Default Value 10 Sett...

Страница 11: ...e 2 Byte Default Value 0 Setting Description 0 auto off disabled 1 27000 0 1s 45min 0 1s step Parameter 157 Output 2 auto off This parameter defines time after which OUT2 will be automatically deactivated Size 2 Byte Default Value 0 Setting Description 0 auto off disabled 1 27000 0 1s 45min 0 1s step Technical Data Dimensions 17 5 x 29 x 13 mm Hardware Platform ZM5101 EAN 5902701701475 IP Class IP...

Страница 12: ...ry Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special...

Отзывы: