FIBARO FIBEFGBS-222 Скачать руководство пользователя страница 5

Connection with gate opener

 
Smart Implant can be connected to different devices to control them. In this example it is connected to gate opener with impulse input (every impulse will start and
stop the gate motor, alternately opening/closing).
 
1. Disconnect Power
2. Connect with the diagram below
 

 
3. Verify the correctness of connection.
4. Power the device.
5. Add the device to the Z-Wave network.
6. Change values of parameters:

Connected to IN1 and OUT1:

Change parameter 20 to 2 (monostable button)

Change parameter 156 to 1 (0.1s)

Connected to IN2 and OUT2:

Change parameter 21 to 2 (monostable button)

Change parameter 157 to 1 (0.1s)

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be 

added to an existing wireless network

 to communicate with the

devices of this network. This process is called 

Inclusion

.

Devices can also be removed from a network. This process is called 

Exclusion

. Both processes are initiated by the primary controller of the Z-Wave network. This

controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

1.Power the device.
2.Set the main controller in (Security/non-Security Mode) add mode (see the controllers manual).
3.Quickly, triple click button on the device housing or switch connected to IN1 or IN2.
4.If you are adding in Security S2 Authenticated, scan the DSK QR code or input the 5-digit PIN code (label on the bottom of the box).
5.LED will start blinking yellow, wait for the adding process to end.
6.Successful adding will be confirmed by the Z-Wave controllers message. To add the device to the Z-Wave network using

Exclusion

1.Power the device.
2.Set the main controller into remove mode (see the controllers manual).
3.Quickly, triple click button on the device housing or switch connected to IN1 or IN2.
4.LED will start blinking yellow, wait for the removing process to end.
5.Successful removing will be confirmed by the Z-Wave controllers message.

Product Usage

Tips for arranging the antenna:

Locate the antenna as far from metal elements as possible (connecting wires, bracket rings, etc.) in order to prevent interferences,

Metal surfaces in the direct vicinity of the antenna (e.g. flush mounted metal boxes, metal door frames) may impair signal reception!

Do not

 cut or shorten the antenna - its length is perfectly matched to the band in which the system operates.

Make sure no part of the antenna sticks out of the wall switch box.

 

Содержание FIBEFGBS-222

Страница 1: ...mation about Z Wave technology devices white papers etc please refer to www z wave info Product Description FIBARO Smart Implant allows to enhance the functionality of wired sensors and other devices by adding Z Wave network communication You can connect binary sensors analog sensors DS18B20 temperature sensors or DHT22 humidity and temperature sensor to report their readings to the Z Wave control...

Страница 2: ...ection with regular alarm line 1 alarm sensor 2 alarm system hub Example connection with parametric alarm line 1 alarm sensor 2 alarm system hub 3 Verify correctness of connection 4 Arrange the device and its antenna in the housing 5 Power the device 6 Add the device to the Z Wave network 7 Change values of parameters Connected to IN1 Normally close change parameter 20 to 0 Normally open change pa...

Страница 3: ...o the Z Wave network 6 Change values of parameters Connected to IN1 change parameter 20 to 4 Connected to IN2 change parameter 21 to 4 Connection with 2 wire 0 10V Sensor The 2 wire analog sensor requires pull up resistor You can connect up to 2 analog sensors to IN1 IN2 terminals The 12V supply is required for these type of sensors 1 Disconnect Power 2 Connect with the diagram below 3 Verify the ...

Страница 4: ...ry sensors to IN1 IN2 terminals 1 Disconnect Power 2 Connect with the diagram below 3 Verify the correctness of connection 4 Power the device 5 Add the device to the Z Wave network 6 Change values of parameters 6 1 Binary sensor Connected to IN1 Normally close change parameter 20 to 0 Normally open change parameter 20 to 1 Connected to IN2 Normally close change parameter 21 to 0 Normally open chan...

Страница 5: ...ht on the device Inclusion 1 Power the device 2 Set the main controller in Security non Security Mode add mode see the controllers manual 3 Quickly triple click button on the device housing or switch connected to IN1 or IN2 4 If you are adding in Security S2 Authenticated scan the DSK QR code or input the 5 digit PIN code label on the bottom of the box 5 LED will start blinking yellow wait for the...

Страница 6: ...ommunication with the main controller through other modules repeaters Visual indicator glowing yellow the device communicates with the main controller through the other modules After 2 seconds the device will retry to establish a direct communication with the main controller which will be signalled with visual indicator pulsing green Visual indicator pulsing violet the device does communicate at t...

Страница 7: ...ired wakeup interval and the node ID of the controller If the device was included by a static controller this controller will usually perform all necessary configurations The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device To wakeup the device please perform the following action FIBARO Smart Implant is powered using DC power supply unit so it...

Страница 8: ...ntral Scene 3 Bistable button Central Scene 4 Analog input without internal pull up Sensor Multilevel 5 Analog input with internal pullup Sensor Multilevel Parameter 21 Input 2 operating mode This parameter allows to choose mode of 2nd input Size 1 Byte Default Value 2 Setting Description 0 Normally closed alarm input Notification CC 1 Normally open alarm input Notification CC 2 Monostable button ...

Страница 9: ...Input 2 value sent to 3rd association group when activated This parameter defines value sent to devices in 3rd association group when IN2 input is triggered using Basic Command Class Size 2 Byte Default Value 255 Setting Description 0 255 value send to devices Parameter 54 Input 2 value sent to 3rd association group when deactivated This parameter defines value sent to devices in 2nd association g...

Страница 10: ... connected DS18B20 or DHT22 sensors Size 2 Byte Default Value 0 Setting Description 0 periodical reports disabled 60 32400 60s 9h Parameter 150 Input 1 sensitivity This parameter defines the inertia time of IN1 input in alarm modes Adjust this parameter to prevent bouncing or signal disruptions Parameter is relevant only if parameter 20 is set to 0 or 1 alarm mode Size 1 Byte Default Value 10 Sett...

Страница 11: ...e 2 Byte Default Value 0 Setting Description 0 auto off disabled 1 27000 0 1s 45min 0 1s step Parameter 157 Output 2 auto off This parameter defines time after which OUT2 will be automatically deactivated Size 2 Byte Default Value 0 Setting Description 0 auto off disabled 1 27000 0 1s 45min 0 1s step Technical Data Dimensions 17 5 x 29 x 13 mm Hardware Platform ZM5101 EAN 5902701701475 IP Class IP...

Страница 12: ...ry Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special...

Отзывы: