Parameter 154: Output 1 - logic of operation
This parameter defines logic of OUT1 output operation.
Size: 1 Byte, Default Value: 0
Setting
Description
0
contacts normally open / closed when active
1
contacts normally closed / open when active
Parameter 155: Output 2 - logic of operation
This parameter defines logic of OUT2 output operation.
Size: 1 Byte, Default Value: 0
Setting
Description
0
contacts normally open / closed when active
1
contacts normally closed / open when active
Parameter 156: Output 1 - auto off
This parameter defines time after which OUT1 will be automatically deactivated.
Size: 2 Byte, Default Value: 0
Setting
Description
0
auto off disabled
1 - 27000
(0.1s-45min, 0.1s step)
Parameter 157: Output 2 - auto off
This parameter defines time after which OUT2 will be automatically deactivated.
Size: 2 Byte, Default Value: 0
Setting
Description
0
auto off disabled
1 - 27000
(0.1s-45min, 0.1s step)
Technical Data
Dimensions
17,5 x 29 x 13 mm
Hardware Platform
ZM5101
EAN
5902701701475
IP Class
IP 20
Voltage
9-30 V
Load
150mA
Device Type
Notification Sensor
Network Operation
Always On Slave
Z-Wave Version
6.81.01
Certification ID
ZC10-19046414
Z-Wave Product Id
0x010F.0x0502.0x1000
Color
White
Supported Notification Types
Home SecuritySystem
Sensors
Open/Closed (Binary)
Frequency
Europe - 868,4 Mhz
Maximum transmission power
5 mW
Supported Command Classes
Application Status