FIBARO DOOR/WINDOW SENSOR 2 Скачать руководство пользователя страница 15

15

REGULATIOnS

#9: Regulations

This device complies with Part 15 of the FCC Rules 

Operation is subject to the following two conditions:

1. This device may not cause harmful interference

2. This device must accept any interference received, including interfe-

rence that may cause undesired operation. This equipment has been 

tested and found to comply with the limits for a Class B digital device, 

pursuant to part 15 of the FCC Rules. These limits are designed to pro-

vide reasonable protection against harmful interference in a residen-

tial installation. This equipment generates, uses and can radiate radio 

frequency energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a par-

ticular installation. If this equipment does cause harmful interference 

to radio or television reception, which can be determined by turning 

the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:

•  Reorient or relocate the receiving antenna.

•  Increase the separation between the equipment and receiver.

•  Connect the equipment into an outlet on a circuit different from 

that to which the receiver is connected.

•  Consult the dealer or an experienced radio/TV technician for help.

Note

Changes and modifications not expressly approved by the manufactu-

rer or registrant of this equipment can void your authority to operate 

this equipment under Federal Communications Commission’s rules.

Industry Canada (IC) Compliance Notice

This device complies with Industry Canada license-exempt RSSs. Ope-

ration is subject to the following two conditions: (1) this device may 

not cause interference, and (2) this device must accept any interferen-

ce, including interference that may cause undesired operation of the 

device.
Cet appareil est conforme aux normes d’exemption de licence RSS d’In-

dustry Canada. Son fonctionnement est soumis aux deux conditions 

suivantes : (1) cet appareil ne doit pas causer d’interférence et (2) cet 

appareil doit accepter toute interférence, notamment les interférences 

qui peuvent affecter son fonctionnement.

Legal Notices

All information, including, but not limited to, information regarding the 

features, functionality, and/or other product specification are subject 

to change without notice. Fibaro reserves all rights to revise or upda-

te its products, software, or documentation without any obligation to 

notify any individual or entity.

FIBARO  and Fibar Group logo are trademarks of Fibar Group S.A. All 

Содержание DOOR/WINDOW SENSOR 2

Страница 1: ...1 Description and features 3 2 Basic activation 4 3 Adding removing the device 5 4 Physical installation 6 5 Operating the device 7 6 Association 9 7 Advanced parameters 10 8 Specifications 14 9 Regulations 15 O P E R A T I N G M A N U A L EN v1 0 ...

Страница 2: ...fy the compliance with additional standards General information about the FIBARO System FIBARO is a wireless smart home automation system based on the Z Wave protocol All of available devices can be controlled through a computer PC or Mac smartphone or tablet Z Wave devices are not only receivers but can also repeat the signal increasing the Z Wave network s range It gives advantage over tradition...

Страница 3: ...with the Z Wave Plus standard Changing the device s status will automatically send signal to the Z Wave controller and associated devices Sensor can be used to trigger scenes and wherever there is a need for information about opening or closing of doors windows garage doors etc Opening is detected by separating the sensor s body and the magnet In addition the FIBARO Door Window Sensor 2 is equippe...

Страница 4: ...ctivation 2 Basic activation 1 Take off the cover 2 Remove the battery blocker 3 Close the cover 4 Add the device see Adding removing the device on page 5 5 Install the device see Physical installation on page 6 ...

Страница 5: ...Wave controller s message Removing Exclusion Z Wave device learning mode allowing to remove the device from existing Z Wave network To remove the device from the Z Wave network 1 Close the cover 2 Place the Door Window Sensor 2 within the direct range of your Z Wave controller 3 Set the main controller into remove mode see the controller s manual 4 Quickly three times press one of the TMP buttons ...

Страница 6: ...2 Stick the device onto the door window frame 3 Peel off the protective layer from the sticker on the magnet 4 Stick the magnet onto the moving part of the door window no further than 5mm from the sensor Correct positioning of the magnet in relation to the Sensor vertical line marks should align Positioning of the Sensor and the magnet max 5 mm ...

Страница 7: ...onally tamper button allows to control the device directly TMP button TMP button Waking up the Door Window Sensor 2 The Door Window Sensor 2 needs to be woken up to receive informa tion about the new configuration from the controller like parameters and associations To wake up the sensor manually click one of the TMP buttons while the other button is pressed Controlling the Door Window Sensor 2 wi...

Страница 8: ...e from the Z Wave network Use reset procedure only if the primary con troller is missing or inoperable Certain device removal can be achieved by the pro cedure of removing described in Adding removing the device on page 5 i Replacing the battery In FIBARO Home Center controller current battery level is displayed in the interface If a battery icon turns red it means the battery needs replacement NO...

Страница 9: ...e Advanced tab 3 Specify to which group and what devices are to be associated 4 Save the changes 5 Wake up the device manually or wait for the next automatic wake up NOTE Association allows transfer of control commands between devices without par ticipation of the main controller Direct range between devices is recom mended i The Door Window Sensor 2 in 2nd and 3rd group allows to control 5 device...

Страница 10: ...g 6 Parameter size 1 byte Wake up interval Available settings 0 or 3600 64800 in seconds 1 18h 3600s 1h step Default setting 21600 6h The Door Window Sensor will wake up after each defined time inter val and always try to connect with the main controller After a suc cessful communication attempt the sensor will update configuration parameters associations and settings and will go into standby mode...

Страница 11: ...osing parameter 13 Default setting 0 Parameter size 1 byte 12 Association for opening value sent Value sent to devices in 2nd association group when opening is detected The value of 0 turns OFF the device 255 turns it ON In case of associating devices allowing smooth control values 1 99 allow to set an associated device to a specified level Available settings 0 99 or 255 Default setting 255 Parame...

Страница 12: ...ife will shorten Available settings 0 temperature measurements disabled 5 32400 time in seconds Default setting 300 5min Parameter size 2 bytes 51 Temperature reports threshold This parameter defines the change of temperature in comparison with last reported resulting in temperature report being sent to the main controller Available settings 0 temperature reports based on threshold disabled 1 300 ...

Страница 13: ...larm 2 low temperature alarm 3 high and low temperature alarms enabled Default setting 0 Parameter size 1 byte 55 High temperature alarm threshold If temperature is higher than set value overheat notification will be sent and high temperature scene will be triggered if activated Available settings 1 600 0 1 60 C 0 1 C step Default setting 350 35 Parameter size 2 bytes 56 Low temperature alarm thre...

Страница 14: ... ANZ 869 0 MHz RU up to 50m 164ft outdoors up to 40m 131ft indoors depending on terrain and building structure Indoor use only 0 40 C 32 104 F 0 60 C 32 104 F 0 5 C 0 9 F 71 x 18 x 18 mm 2 8 x 0 7 x 0 7 inch 8 Specifications NOTE Radio frequency of individual device must be same as your Z Wave controller Check information on the box or consult your dealer if you are not sure i CAUTION Using batter...

Страница 15: ...the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Note Changes and modifications not expressly approved by the manufactu rer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules Industry Canada IC Compliance No...

Страница 16: ...quency electric machineries shall not affect the navigation safety nor interfere a legal communication if an interference is found the service will be suspended until improvement is made and the interference no longer exists 第十二條 經型式認證合格之低功率射頻電機 非經許可 公司 商號或使用 者均不得擅自變更頻率 加大功率或變更原設計之特性及功能 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信 經發現 有干擾現象時 應立即停用 並改善至無干擾時方得繼續使用 前項合法通信 指依電信法規定作業之無線電通信 低功率射頻電機須忍受合法通信或工業 科學及醫療用電波...

Отзывы: