FIAMA P2X T Series Скачать руководство пользователя страница 2

data: 13/01/16

File: P2XT_smd_ing.doc 

pag 2 di 10

Input description

The positioner is controlled by 4 opto-isolated inputs, that are:

START: 

active from NA to NC, it causes the positioning start and brings different effects according to
the working mode (see working mode at page 4).

EMERGENCY:  it must be normally closed, if open it blocks or interrupts the positioning
PIECECOUNTER: at the end of each positioning the instrument expects a changing over of the piece counter

input from NC to NA to proceed to the next positioning.  NB: if not used connect it in parallel
with the 

START

 input.

PRESET: 

the changing over from NA to NC causes the reset or the preset loading according to the
zero reset procedure constant (see zero reset procedure page 6).

For switches see the connections scheme at page 10.

Output descriptions

The positioner is able to manage 3 relays outputs:

START/STOP: 

normally open switch that closes to allow positioning

FORWARD/BACKWARD:

change-over switch that controls the direction of motion of the positioned axis

END POSITIONING: 

normally open switch that closes at positioning end

ANALOG OUTPUT

voltage selectable  0÷10V or –10÷10V, and current 4-20mA

For switches see the connections scheme at page 10

PROGRAMMING

The following keys are used to programme:

PGM

to start and to leave the programming mode of the instrument
to change from one constant to another or to increase the digit value during modification
or to change from one digit to the next one

RESET/ENTER

to confirm inserted values

To enter programming mode is necessary to press the 

PGM 

key ; on the display you will see the

write

  (immediate positioning); by the key    you can run through the menus 

-0/

-0/

-0/

-0/

 (quote),

 (cycles),  

/

/

/

/

  (costanti),  

+

+

+

+

(manual),  

//

//

//

//

(test)  whose functions are the following:

to insert an immediate positioning dimension (see next paragraph)

-0/

-0/

-0/

-0/

to insert dimensions and positioning programs, number of pieces and cycles (see next
paragraph)

per impostare il numero di cicli del programma di posizionamento da eseguire (vedi
“Impostazione del numero di cicli” a pagina 4)

/

/

/

/

to enter the machinery constants of the positioner (see Setting up of Machinery Constants
at page 4)

+

+

+

+

to change to manual operating mode of positioner (see Manual Operating mode at page 7)

//

//

//

//

to test inputs and outputs (see Test function at page 7)

Содержание P2X T Series

Страница 1: ...the inputs Start Emergency Preset Pieces counter all optoisolated To optimize the accuracy of the positioning P2X_T requires entering a few parameters in order to compensate the inertia of the system the clearances and the wear of the mechanical couplings Other features of the instrument are semiautomatic automatic manual absolute relative and line working modes 99 positioning dimensions memory an...

Страница 2: ...ING normally open switch that closes at positioning end ANALOG OUTPUT voltage selectable 0 10V or 10 10V and current 4 20mA For switches see the connections scheme at page 10 PROGRAMMING The following keys are used to programme PGM to start and to leave the programming mode of the instrument to change from one constant to another or to increase the digit value during modification or to change from...

Страница 3: ...M to enter the programming mode the writing appears on the display Press to select the menu 0 0 0 0 Press RESET ENTER the display show 000 with the first digit flashing this is the password request With the key increase of the flashing digit and selection of the flashing digit set the value 273 and confirm by RESET ENTER N B In the machinery constant exist one constant for remove the dimensions fr...

Страница 4: ...onstant of the positioner are the followings Blade Thickness By setting a not zero value all the positioning dimensions were set will be increased with this quantity These constant is used the aplicatios witch expect a cut with material removal PreStop It represents the inertia of positioned axis the positioner disables the start output when the axis reaches a dimension equal to the difference bet...

Страница 5: ... enabled only if Shifting Dimension is set up not zero value it can be set up from 0 to 9999 milliseconds Displayed value for an encoder turn The instrument can correct counted pulses by multiplying them by a coefficient amounting to the ratio between the and constants if the two constants are opportunely set it is possible to display the wished value for a given number of pulses counted on inputs...

Страница 6: ... maximum speed the positioner produces an acceleration ramp with a time constant that may be set up between 50 to 9999 milliseconds Time constant for deceleration ramp During the positiong reached the Slow value by the passing from the speed Fast to the speed Slow it produces a decelaration ramp with a time constant that may be set up between 50 and 9999 milliseconds Value of the analog output for...

Страница 7: ...ed From tenth of mm to thousandths of an inch From tenth of mm to hundredths of an inch From mm to hundredths of an inch From mm to tenths of an inch From cm to hundredths of an inch From dm to inches Sexagesimal degrees with display in degrees and prime numbers Sexagesimal degrees with display in degrees Baud rate for serial output 0 0 0 0 Not used in this version don t change or set to MANUAL WO...

Страница 8: ...ENTER on the display 4 dashes are displayed its last right one flashes Each dash represents an output From right to left the dashes are represented as follows START STOP SLOW FAST FORWARD BACKWARD POSITIONING END see next picture The flashing dash indicates the selected output The dash position indicates the output condition an upper lower position means an active inactive idle output Press to sel...

Страница 9: ...h is closed as much as the set value of the Duration of Positioning End Impulse constant Before positioning to the next dimension the instrument waits for the changing over from closed to open of the PIECECOUNTER input and the permission from the START input according to working mode procedure semiautomatic or automatic N B if the counterpiece input is not used it is necessary to connect parallell...

Страница 10: ...analogic output Current analogic output Scheme of transducers connections max 60mA INPUT JUNCTION BOX 1 2 5 4 3 6 7 8 9 10 11 12 13 12V output B output B GND output A output A TX RS232 per RS485 RX RS232 per RS485 GND RS232 encoder START input PRESET input CONTAPEZZI input EMERGENZA input GND A A B B 12V optional 5 3 6 4 2 1 GND A B 12V A B GND A B Vcc Bidirectional encoder open collector output o...

Страница 11: ...ssibility to create working programmes Stores 99 steps of program memory with the possibility of specifying the number of pieces and the number of cycle repeats Data storage with the machine switched off by EEPROM memory Manual Preset Extractable terminal junction box Input output test 3 relays output 120 Vac 0 5A 24Vdc 1A start stop forward backward positioning end 4 inputs ON OFF optoisolated 12...

Отзывы: