data: 13/01/16
File: P2XT_smd_ing.doc
pag 9 di 10
POSITIONER OPERATING
Once the instrument has been connected, set the machinery constants and insert dimensions and positioning
programs as it is described in the previous paragraphs.
To choose the positioning dimension or the program to be executed, press
RESET/ENTER
and the auxiliary
display will appears
and the first dimension index of the posiotioning with the first digit flashing; select
the start dimension using the keys and
and confirm by
RESET/ENTER
.
Being the EMERGENCY input closed, activate the START input (changing over from open to closed); the
positioner will move the axis toward the first dimension.
As soon as the set dimension has been reached, the instrument opens the start switch and close the
positioning end switch, which is closed as much as the set value of the “Duration of Positioning End Impulse”
constant.
Before positioning to the next dimension the instrument waits for the changing over from closed to open of the
PIECECOUNTER input and the permission from the START input, according to working mode (procedure)
(semiautomatic or automatic).
N.B.
if the counterpiece input is not used, it is necessary to connect parallelly to the START switch because at
the end of each positioning the positioner waits for the changing over of the counterpiece input.
Once the working program has been completely executed, the instrument starts again from the first dimension
of the program which has just been executed.
During positioning, if you press
PGM
the number of cycles, that have been so far completed, will appear on
the display. If you press
the number of pieces to be manufactured at the current dimension will appear on
the display; if the key is pressed, the number of manufactured pieces will appear on the display.