3
Dimensions & Utility Connections
Water inlet fitting: ¼ inch male flare fitting
Installation
The installation must comply with applicable federal, state, and local codes having jurisdiction at your location. Utilize only
qualified beverage equipment service technicians for installation.
A Service Company Directory may be found on our website,
http://www.fetco.com
.
Setup
1. Before placing the unit, verify that it will fit in the space intended for it, and that
the counter or table will support the weight of the HWD-2105 when filled.
2. When the unit is in position, use a bubble level to level it front to back and side
to side by adjusting the legs.
Water Connection
1. Water inlet is a ¼ inch male flare fitting.
2. Install a shut off valve near the unit to facilitate service.
3. Install a backflow prevention device. A spring loaded double check valve such as a
WATTS® SD-2 or SD-3, two models accepted by most zoning authorities. The
check valve should be as close to the water supply inlet as possible.
4. An inline water filter is highly recommended. It should be installed after the water
shutoff valve and in a position to facilitate filter replacement.
5. Flush the water supply line and filter
before
connecting it to the unit.
6. Verify that the water line provides at least 1½ gpm (5.7lpm), and that the water
pressure is between 40-75 psig (276-517kPa).
Electrical Connection
1. Check serial number plate for the maximum wattage and verify that the actual
voltage at the electrical outlet is compatible with the unit’s specifications.
2. Plug unit in. Note that the plug is NEMA 5-15P or NEMA 5-20P (domestic).
3. The temperature and water tank fill level are pre-set at the factory and there is
no need to turn off the heater during the installation process.
The heating process will start automatically when the tank is filled enough to
cover the heating element
WARNING
-Do not plug-in this equipment or attempt to operate without all covers in place all and screws fastened.
Back panel of HWD-2105
Power
Switch
Water
Supply
Inlet
Appliance Inlet
(attach power cord)
Tank
Drain
Tank
Vent
Warning: Legs are to be adjusted
only to level the unit. Do not extend
them higher than necessary
!
Warning:
To prevent electrical shock, this
unit must be properly grounded.
!
G
W
G
W
NEMA PLUG CONFIGURATION
NEMA 5-15P NEMA 5-20P NEMA 6-15P
Drawing # 1201.00001.00