P167 November 2017
Error Codes
DO NOT CLEAR ERROR CODES UNTIL ERROR IS IDENTIFIED AND CORRECTED
Contact specialized personnel for error codes
Code Description
Possible
Cause
Corrective
Action
001
Software error-error on start up or
corrupted software
Improper start-up or
shutdown
Restart , if still fault: reload software
050
Short-circuit in temperature probe
Probe failure.
Replace probe.
051
Open temperature probe.
Bad probe connection, or
probe failure.
Check all connections. Replace probe
if necessary.
100
Initial Fill Error. Initial fill time was
more than 11 minutes after power
up.
Water supply flow rate is
too low.
Watch for short potting during brew
cycle. Investigate cause of low flow
rate. (Clogged water filter...)
101
Error on refill
Tank did not refill within 3 minutes.
Water supply flow rate is
too low.
Watch for short potting during brew
cycle. Investigate cause of low flow
rate. (Clogged water filter…)
201
Heater open, high limit thermostat,
or Solid State Relay (SSR) fault
Failure of: heating
element, SSR, high Limit
or low voltage
Check and replace heating elements if
necessary.
255
Touch pad error
Usually from longer than 2
min contact. Or faulty
reassembly after service
Restart , if still fault: reload software.
If mechanical: reassemble correctly
NO
BSKT
Insert Brew Basket
Brew basket must be in
place
This is a
SAFETY FEATURE
Insert brew basket into brewer rails to
enable brewer
F SAVE & EXIT
Saving changes and exiting PROGRAMMING
The brewer will save changes only from the “F” menu. Do not reboot brewer or toggle ON/OFF-exit as below.
TO EXIT PROGRAMMING & HOW TO SAVE CONTROL SETTING CHANGES
The brewer is in PROGAMMING mode, how to save changes and EXIT
.
From any screen-
Press STOP button
until the EXIT (“F”)
screen appears
From the “F” screen
Press button
2
to
toggle to the EXIT-
YES
screen
From EXIT screen
Press button
1
to
toggle to the SAVE
screen
From SAVE screen
Press button
2
, to
toggle to the SAVE-
YES
screen
To SAVE and EXIT
Press button
1
to
SAVE your changes
and EXIT
NOTE:
User Settings will be erased and overwritten to factory default settings by the following five programming changes
When setting or changing units of display for the tank temperature (F Fahrenheit or C Celsius).
(SETTING B4)
When setting or changing units of display for the volume (G gallons, L liters).
(SETTING B5)
When setting brewer model
The software sets equipment to brewer defaults
(SETTING E2)
When resetting (Reloading) DEFAULTS
(SETTING E5)
When loading from USB (Reloads to defaults )
(SETTING E7)
1
2
3
Programming A-F
A - F
STOP
STOP
1
2
3
EXIT
F NO
+
STOP
STOP
1
2
3
EXIT
F YES
-
STOP
STOP
1
2
3
STOP
STOP
1
2
3
SAVE
F YES
-
STOP
STOP