Go to fetco.com for the latest versions of all information
Page 7
P167 November 2017
B GENERAL
Brewer Operation Control Settings, Adjust Brew Flow Rate
POSITION
Program Items
Factory set Default
Programming
Range
Increments Notes
B1 Tank
Temp.
93° C -or- 200°F
NOTE: Equipment
is metric by default
70° to 96°C
157°F to 205°F
0.5°C
1.0°F
See below
for chart to correct
for high altitude
B2
Brew at Temp.
“YES” ON/OFF
YES/NO
SEE NOTE BELOW
B3 LLC
Sensitivity LOW
LOW is
“normal” for
most water
“HIGH” for R.O.
LOW
or
HIGH
Liquid level control
sensitivity.
High is for reverse
osmosis water or very
pure water.
B4
Temperature Scale
°C
Degrees Celsius
Equipment is
metric by default
C/F
[Switchable Units]
B5
Volume Scale
Liters [Gallons]
Equipment is
metric by default
L/Gal [Switchable
Units]
B6
LEFT brew valve
Flow Rate:
CBS-1152
3.40L/0.9G
2.9-3.9Liter
0.73-1.01Gallon
0.50L
0.01Gal
Adjusts flow rate
B7
RIGHT brew valve
Flow Rate:
CBS-1151&1152
3.40L/0.9G
2.9-3.9Liter
0.73-1.01Gallon
0.50L
0.01Gal
Adjusts flow rate
B8
Low flow rate
from mains
NO OFF/ON
Toggle =/-
YES or NO
Trims fill system for
low supply
Chart to correct for altitude for boiling point
in tank water temperature.
[ft] [m]
Suggested
Setting[°F]
Boiling
point[°F]
Suggested
Setting[°C]
Boiling
point [°C]
0 0 205 212.0 96 100.0
500 152 205
211.0 96
99.5
1000 305 200
210.1 93
98.9
2000 610 200
208.1 93
97.8
2500 762 200
207.2 93
97.3
3000 914 200
206.2 93
96.8
3500 1067 197 205.3 92
96.3
4000 1219 195 204.3 91
95.7
4500 1372 194 203.4 90
95.2
5000 1524 194 202.4 90
94.7
5500 1676 193 201.5 89
94.2
6000 1829 192 200.6 89
93.6
6500 1981 191 199.6 88
93.1
7000 2134 190 198.7 87
92.6
7500 2286 188 197.8 86
92.1
8000 2438 187 196.9 86
91.6
8500 2591 185 196.0 85
91.1
BREW AT TEMPERATURE DEFINITONS
-
--------------------------------------------------------------------------------------------------------
DEFAULT: BREW AT TEMP: “ON”
(FACTORY DEFAULT FOR BREWER)
“BREW at TEMP:
-Batch will not start if tank temperature is
below set point.
-Display will show “HEATING” and hot
water tank temperature
The “BREW START” entry buttons will not
illuminate until the hot water tank reaches
the selected temperature.
Control will allow both sides of dual brewer to operate if one side has
an ongoing brew started and the second side brew is selected.
Notifications shown on screen:
TEXT:
HEATING
Tank above 87°C/189°F-will allow brew at low
temperature. Coffee flavor may be affected
TEXT:
L. HEAT
Tank above 76°C/169°F-will allow brew at low
temperature. Coffee flavor will be noticably affected
------------------------------------------------------------------------------------------------------
USER SELECTABLE OPTION: BREW AT TEMP:
OFF
(Not recommended)
Allows brewing at any temperature above 77°C/170°F
Below 70°C/170°F The red colored ready lights switch turn off-unit
will operate at cold
Hot water tank
not at temp.
Tank temp
STOP is not lit
BREW START
buttons not lit.
and are disabled.
Buttons will
reilluminate when
“READY”
HEATING
160°F
STOP
STOP
Use this formula to compensate for minor discrepancies in actual volume versus programmed volume.
Default Brew Valve Flow Rate—All CBS-1150 V+ Brewers
CBS-1151 &CBS-1152
ml/min
Range
Left and Right Brew Valve FR 3400 ml
+2903 to 3900ml
Use the formula above to determine the correct setting Set lower to increase volume, higher to decrease volume.
See “PROGRAM” B5 and B6 For valve settings and calibration. Factory set brew valve flow rates are in liter/min