EAA
17
GB
* not on all versions included in the scope of deliv-
ery
The illustrations specified are located at the begin-
ning and end of the operating manual.
6
Design
6.1
Energy box
The EAA energy box consists of two sections:
– Section containing electrical components such
as sockets and selector switches for electric
power tools (EW).
– Section containing pneumatic components, in-
cluding connections for pneumatic tools (DW).
6.2
Versions
The different versions offer the following features:
EAA EW CT/SRM/M
– 3 sockets, 1 non-adjustable, unlubricated com-
pressed air connection (not suitable for connect-
ing Festool compressed air sanders!).
– Manually operated slide.
The slides are linked mechanically. Dust can
therefore only be extracted from one machine at
any one time. The slide setting is monitored by a
microswitch.
EAA EW TURBO/M
– 3 sockets, 1 non-adjustable, unlubricated com-
pressed air connection (not suitable for connect-
ing Festool compressed air sanders!).
– Manually operated slide.
Dust can be extracted from two machines at the
same time. The slide setting is monitored by a
microswitch (basic position: slide closed).
EAA EW/DW CT/SRM/M
– 3 sockets, 1 maintenance unit (pressure regula-
tor, condensate trap, lubricator), 2 adjustable, lu-
bricated compressed air connections, 1 non-
adjustable, unlubricated compressed air connec-
tion (not suitable for connecting Festool com-
pressed air sanders!).
– Manually operated slide.
The slides are linked mechanically. Dust can
therefore only be extracted from one machine at
any one time. The slide setting is monitored by a
microswitch.
EAA EW/DW TURBO/M
– 3 sockets, 1 maintenance unit (pressure regula-
tor, condensate trap, lubricator), 2 adjustable, lu-
bricated compressed air connections, 1 non-
adjustable, unlubricated compressed air connec-
tion (not suitable for connecting Festool com-
pressed air sanders!).
– Manually operated slide.
Dust can be extracted from two machines at the
same time. The slide setting is monitored by a
microswitch (basic position: slide closed).
EAA EW/DW TURBO/A
– 3 sockets, 1 maintenance unit (pressure regula-
tor, condensate trap, lubricator), 2 adjustable, lu-
bricated compressed air connections, 1 non-
adjustable, unlubricated compressed air connec-
tion (not suitable for connecting Festool com-
pressed air sanders!).
– Pneumatically operated slides
Dust can be extracted from two machines at the
same time. The slide setting is monitored by a
microswitch (basic position: slide closed).
6.3
Conversion kits
The following conversion kits are available to con-
vert the EAA to a different version at a later time:
CT/SRM/M >> TURBO/M
Modification:
dust extracted by a stationary ex-
traction turbine instead of a mobile dust extractor.
The connector
[3-2]
between the two mechanically
operated slides
[3-1]
must be detached.
EW >> EW/DW (VE2-EAA: 495892)
Modification:
additional connection socket for
pneumatic tools.
An additional maintenance unit (pressure regulator,
condensate trap, lubricator) and a compressed air
module including pneumatic hoses and connection
to electronics via wiring harnesses must be mount-
ed.
Note:
only trained and qualified electricians are
authorised to perform this work!
[1-2]
Aluminium pipe
[1-3]
Permanent socket
[1-4]
On/Off switch
[1-5]
Socket AUTO 2
[1-6]
Compressed air connection* for pneu-
matic tools, adjusted via the pressure reg-
ulator on the maintenance unit
[1-7]
Lock
[1-8]
Extractor connector
[1-9]
Socket AUTO 1
[1-10]
Slide* for opening and closing the
extractor connector
[1-11]
Unlubricated compressed air connection
on EW version only*