2. MPA pneumatic modules
2−24
Festo P.BE−CPX−EA−E N en 0705f
2.5.4
Fault treatment and parametrizing
Depending on the module parametrizing, the faults are sent
to the field bus node, where they can be evaluated according
to the field bus protocol used.
The following diagram show the fault treatment in the MPA
pneumatic modules. Further registering and display of the
faults can be suppressed as desired with the appropriate
module parameters, represented here as switches.
The parameter is described in section 2.4.
2
Fault no. 5
Fault in load
voltage for
valves
Fault message to
field bus node
Monitoring
V
VAL
Fault LEDs
1
0
1
1
Module parameters
(switch position represented = default setting)
2
Module−specific faults
Fig.2/10: Principle of fault treatment and parametrizing
(MPA pneumatic modules VMPA1−...−8 and
VMPA2−...−4)
Содержание VMPA...-FB-EPL Series
Страница 2: ......
Страница 22: ...Contents and general instructions XX Festo P BE CPX EA EN en 0705f ...
Страница 46: ...1 Pneumatic interfaces 1 24 Festo P BE CPX EA EN en 0705f ...
Страница 100: ...3 Overview and connecting technology I O modules 3 30 Festo P BE CPX EA EN en 0705f ...
Страница 101: ...Input modules 4 1 Festo P BE CPX EA EN en 0705f Chapter 4 Type CPX 4DE CPX 8DE CPX 8DE D CPX 16DE CPX M 16DE D CPX 8NDE ...
Страница 141: ...Output modules 5 1 Festo P BE CPX EA EN en 0705f Chapter 5 Type CPX 4DA CPX 8DA CPX 8DA H ...
Страница 171: ...Multi I O modules 6 1 Festo P BE CPX EA EN en 0705f Chapter 6 Type CPX 8DE 8DA ...
Страница 191: ...Technical appendix A 1 Festo P BE CPX EA EN en 0705f Appendix A ...
Страница 223: ...Index B 1 Festo P BE CPX EA EN en 0705f Appendix B ...
Страница 224: ...B Index B 2 Festo P BE CPX EA EN en 0705f Contents B Index B 1 ...