en
Operatinginstructions
8068454
1705c
[8068456]
Vacuum block
VABF-S4-1-V2B1...
Страница 1: ...en Operating instructions 8068454 1705c 8068456 Vacuum block VABF S4 1 V2B1...
Страница 2: ...th or serious injuries Caution Hazards that can cause minor injuries Other symbols Note Material damage or loss of function Recommendations tips references to other documentation Essential or useful a...
Страница 3: ...10 3 Requirements for product use 12 4 Installation 13 4 1 Mechanical 13 4 2 Pneumatic 14 4 3 Electric 14 5 Quick commissioning with default settings 15 6 Commissioning 16 6 1 Symbolic LCD display 18...
Страница 4: ...VABF S4 1 V2B1 4 Festo VABF S4 1 V2B1 1705c English 8 Maintenance and care 25 9 Disassembly 25 10 Fault clearance 26 11 Accessories 28 12 Technical data 29 13 Menu structure 32...
Страница 5: ...buttons 2 Plug connector for electrical connection and vacuum sensing M12 4 pin 3 LED signal status display solenoid valve 4 Manual override vacuum generation 5 Manual override for ejector pulse only...
Страница 6: ...ric LCD display vacuum display special display 4 Toolbar for functions 5 EDIT button 6 DOWN key B key 7 UP key A key 8 Segment display Tab 4 and Tab 5 Fig 2 Display Note The operating keys are designa...
Страница 7: ...solenoid valve with mechanical manual override for vacuum generation The ejector pulse cannot be switched via the mechanical manual override when the power supply is activated Silencer Actuation and...
Страница 8: ...ule Tab 2 Air saving Controlled via internal electronics of the vacuum block Controlled via internal electronics of the vacuum block Maintain vacuum in valve mid position 1 Ejection Not controlled Con...
Страница 9: ...ly Generate vacuum Generate vacuum Air saving Generate vacuum Ejection Normal position 1 Normal position 1 Normal position 1 1 Normal position means the vacuum block is not in the Generate vacuum Air...
Страница 10: ...or the generated vacuum is monitored via an integrated pressure sensor Vacuum generation reverts to a self holding phase after reaching the setpoint value The vacuum block controls the vacuum generati...
Страница 11: ...ng function is reached for the vacuum vacuum generation is automatically switched off Non return valves prevent the reduction of the vacuum Nonetheless leakage e g due to rough workpiece surfaces will...
Страница 12: ...tus displays of the solenoid valve are shown at the bottom of the diagram Hysteresis Vacuum 0 Excess pressure 1 2 3 4 Valve terminal inputs LED display on valve Pressure sensor outputs 1 Threshold val...
Страница 13: ...y unauthorised third parties Chapter 6 3 Edit mode Note The vacuum is measured as relative pressure The displayed pressure value is the actual pressure difference from ambient pressure The attainable...
Страница 14: ...on 4 1 Mechanical 1 2 3 4 1 Seal 2 Vacuum block 3 Push in fitting QS port 2 vacuum 4 Blanking plug port 4 Fig 5 Installation Secure the vacuum block to the manifold sub base VABV S4 1S G14 2T2 of the...
Страница 15: ...erence Make sure that the signal lines are always shorter than 5 m Note Electrical components may become damaged if the maximum permitted voltage is ex ceeded Make sure that the operating voltage supp...
Страница 16: ...eristics threshold value comparator Switching point 700 mbar Hysteresis 200 mbar Switching characteristic NO normally open N O contact Channel B vacuum sensing Switching characteristics threshold valu...
Страница 17: ...nfirm values In order to avoid damaging the EDIT button please press it using a blunt object The basic status can be reached from other modes by pressing EDIT button 3 s or Expiration of a monitoring...
Страница 18: ...intensity of the ejector pulse can be adjusted You can set the intensity of the ejector pulse by adjusting the flow control screw 7 Fig 1 Control sections ports displays and assemblies 1 Screw the fl...
Страница 19: ...ontact X X min max Extreme values minimum maximum input measured value In A1 1 X TeachIn TeachIn mode active X Lock Security code active block to prevent unauthorised parameterisation X X Special menu...
Страница 20: ...P or SP min and SP max hysteresis HY switching characteristic NO NC Extreme values of input values minimum pressure value min In order to delete the minimum value press the EDIT button briefly maximum...
Страница 21: ...use serious injury to people and material damage Note that if the switching characteristics of the switching outputs is modified in the EDIT mode the new status will be effective immediately Note The...
Страница 22: ...resis flashes 7 Adjust the hysteresis HY e g 200 by pressing the UP DOWN keys A B keys 8 Press the EDIT button to confirm the set value NO or NC flashes 9 Select the switching characteristic NO by pre...
Страница 23: ...east 50 mbar above the switching point of the vacuum sensing Out B To do this reduce the hysteresis of Out A if necessary Note Additional setting options can be found in the accompanying pressure sens...
Страница 24: ...lenoid coil 14 can only be switched with the manual override when it is not supplied with power no voltage at connector M12 An ejector pulse via the manual override is not possible during normal opera...
Страница 25: ...in a clockwise direction The valve reverts to the switching position and remains switched Then turn the plunger 90 in an anti clockwise direction Then release the plunger The valve reverts to the rest...
Страница 26: ...proceed as follows 1 Switch off the operating voltage M12 2 Press all three setting elements UP key DOWN key EDIT button simultaneously and keep them depressed 3 Switch the operating voltage back on...
Страница 27: ...iameter is too small Replace the hose Hose requirements Chapter 4 2 Flow control screw is closed Open the flow control screw No display Supply voltage not applied or permitted operating voltage not pr...
Страница 28: ...supply plate directly next to the vacuum block optionally create a separate pressure zone see manual VTSA VTSA F Switching thresholds or hysteresis set incorrectly Correct switching thresholds and or...
Страница 29: ...ing cable M12x1 straight socket open end 5 pin 4 wire 5 m NEBU M12G5 K 5 LE4 Connecting cable M12x1 straight socket open end 5 pin 4 wire 2 5 m NEBU M12G5 K 2 5 LE4 Connecting cable M12x1 straight plu...
Страница 30: ...outputs Max output current mA 50 Voltage drop V 1 5 Maximum capacitive load DC nF 100 Protective functions Inductive protective circuit Adapted to MZ MY ME coils Protection against short circuit Yes...
Страница 31: ...re 1 Low pressure 2 Operating pressure 1 2 Fig 6 Low pressure generated as a function of the vacuum block s operating pressure Air consumption 1 Air consumption 2 Operating pressure 1 2 Fig 7 Air cons...
Страница 32: ...VABF S4 1 V2B1 32 Festo VABF S4 1 V2B1 1705c English Suction rate 1 Suction rate 2 Operating pressure 1 2 Fig 8 Suction rate dependent on operating pressure of the vacuum block...
Страница 33: ...teaching the measured value TP1 here Symbol on the display flashes here Out A Security code active lock blocked against unauthorised programming Security code inactive Lock Press key A key here Press...
Страница 34: ...VABF S4 1 V2B1 34 Festo VABF S4 1 V2B1 1705c English 1 2 1 Switch displayed input value A B 2 Display delete minimum maximum value Fig 10 SHOW mode...
Страница 35: ...VABF S4 1 V2B1 Festo VABF S4 1 V2B1 1705c English 35 Fig 11 EDIT mode...
Страница 36: ...zation is prohibited Offenders will be liable for damages All rights re served in the event that a patent utility model or design patent is registered Copyright Festo AG Co KG Ruiter Stra e 82 73734 E...