Configuring the field bus module
You can configure the field bus module with the software pack-
age WinPISA or with the operating panel.
Number of configurable inputs and outputs
The SPC200 communicates with the Interbus module via an
internal I/O field (internal inputs/outputs). The permitted number
of configurable inputs and outputs depends on the operating
mode of the SPC200. This is summarized in the following table.
Operating
mode of the
SPC200
Max. address
range *)
Function of the inputs/outputs
Start/Stop
I10.0 - I13.15
I10.0 - I10.15
for control signals and
freely prog. inputs
I11.0 - I13.15
for freely programmable
inputs
(optional)
Q10.0 - Q13.15
Q10.0...Q10.15
for control signals and
freely prog. outputs
Q11.0 - Q13.15
for freely programmable
outputs
(optional)
Record
selection
I10.0 - I11.15
I10.0 - I10.15
for control signals
I11.0 - I11.15
for record number
Q10.0 - Q10.15
Q10.0 - Q10.15
for control signals
*) Address specification as seen by the SPC200
In record selection mode, the process data capacity is preset
fixed at 4I/4O-byte (2 process data words; 32 bits). In start/stop
mode, a process data capacity between 2....8 I/O byte (1...4
process data words; 16, 32, 48 or 64 bits) can be selected.
Eng
li
s
h
SPC200-COM-IBS
16
0503a