2. Fitting
2-4
Festo SEC-ST-48-6-P01-EN en 0111NH
Please note
Screening can be attached to the M4 earthing screws
intended for this purpose.
Fastening screws must not be used as earthing screws.
The devices in this series are intended as compact units for
fitting into a control cabinet or onto a wall. The loss of power
which occurs in operation and the subsequent heating of the
unit depends on the output. The SEC-ST must be cooled with
forced ventilation by means of the fan supplied with the prod-
uct. There must be a gap of at least 3 cm on all sides for suffi-
cient cooling.