Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Page 177
Vision Sensor Manual
- All Jobs must be in triggered mode
- Ready signal must be high when trigger sequence starts
4.6.4.2.4 Input: Teach temp. / perm.
For re-teaching samples of all detectors of the current job. Only possible when Ready = high. A rising
edge initiates teaching, during which a high level must exist at least until the next trigger, so that an image
of an inspection part can be recorded in the correct position. Ready is set to low and remains low until
teaching has been completed. Storage is either temporary (only in RAM), or permanent (in flash)
according to the setting.
Fig. 177: Input timing, Teach
Attention!
The functions Job 1 or 2, Job 1 ... n or teach temp. /perm. can only be used in trigger mode
4.6.4.2.5 Input, Repeat Mode Enable, with Trigger
Images are captured and evaluated as long as,
this input is on high level and none of the following stop criteria is fulfillled:
- "Overall job result" = positive (access via Output/Digital output)
- "Max. cycle time" is not elapsed (if active)
If "Repeat mode enable" is used, this implicitly causes function "Trigger enable" at the same time. That
means only if a high signal is at this input, triggers are accepted and executed
Fig. 178: Input, Repeat Mode Enable, with Trigger