Page 258
Vision Sensor SBSI/SBSC-EN, 8062650 - 1607b - 13/09/2016
Vision Sensor Manual
* Port 2003, TCP
* Port 2004, TCP
To communicate between PLC (PLC- PC also) and the SBS the following ports are used.
* Port 2005, TCP (Implicit results, that means, user configured result data)
* Port 2006, TCP (Explicit requests, e.g. trigger or job switch)
If the ports 2005 or 2006 are changed in Vision Sensor Configuration Studio, the according ports also
must be enabled in the firewall by the administrator.
If the interface EtherNet/IP is used the following two ports must be enabled too.
* Port 2222, UDP (EtherNet/IP)
* Port 44818, TCP (EtherNet/IP)
5.5.5 Access to SBS via network
Exemplary values for IP etc.
Access to SBS 1 from PC 1, if in same subnet.
l
Via Vision Sensor Device Manager (/find)
Access to SBS 2 from PC1, if in different subnet.
Only if:
l
Gateway is set correct in sensor 2 (here to 192.168.30.1) - and
l
in Vision Sensor Device Manager via Add- IP- the sensor IP of sensor 2 is set correct
> now the SBS 2 appears in the list „Active Sensors“ in Vision Sensor Device Manager !