PGVA Manual
Festo SE & Co. KG
Page 9 of 20
Modbus registers address spaces
Register name
and address
Type
Offset
Scaling Action when read Action when written
Vacuum actual
ADDR: 0x100
Input register
Dimension:
mbar
-
1498.334
1.332
Acquires actual
pressure in the
vacuum tank and
returns it as
Modbus slave
FC04 reply
N/A
Pressure actual
ADDR: 0x101
Input register
Dimension:
mbar
-
1498.334
1.332
Acquire actual
pressure in the
pressure tank
N/A
Output
pressure actual
ADDR: 0x102
Input register
Dimension:
mbar
-500 0.244
Acquire actual
pressure and
vacuum box
output pressure
N/A
Firmware
version.version
ADDR: 0x103
Input register
Dimension: <
version>.
<sub_version>
.<build>
0 1
Returns firmware
version
(hardcoded value
in code flash)
N/A
Firmware
version.sub_ver
sion
ADDR: 0x104
Input register
Dimension:
<version>.
<
sub_version>.
<build>
0 1
Returns firmware
sub_version
(hardcoded value
in code flash)
N/A
Firmware
version.build
ADDR: 0x105
Input register
Dimension:
<version>.
<sub_version>
.< build>
0 1
Returns firmware
build (hardcoded
value in code
flash)
N/A
PGVA status
word
ADDR: 0x106
Input register
Bitfield.
Please refer
to Table 1.
below.
0 1
Reads the status
of the PGVA
N/A
Dispense valve
opening times
(MSH):
ADDR: 0x107
Input register
Dimension:
Upper 16 bits
of a 32-bit
integer
0 1
Reads the most-
significant
halfword of the
32-bit counter for
the total number
N/A