PGVA Manual
Festo SE & Co. KG
Page 15 of 20
Manual trigger
ADDR: 0x1011
Holding
register
Dimension: 0
or 1
0 1
Reads the
current state of
the output.
Writing 1 to this register
opens the output valve, 0 –
closes it
Store to
EEPROM
ADDR: 0x1064
Holding
register
Dimension:
don’t care
N/A N/A N/A
Stores the configuration
registers (marked with
*
and
**
) to the EEPROM. Value
written to this register is
meaningless.
Reset pump life
counter
ADDR: 0x1065
Holding
register
Dimension:
don’t care
N/A N/A N/A
Resets the life counter for
the pump.
Start pre-
calibration
ADDR: 0x1066
Holding
register
Dimension:
don’t care
N/A N/A N/A
Starts device’s pre-
calibration procedure in
order to precisely determine
the voltage range.
Adjust
calibration
setpoints
ADDR: 0x1067
Holding
register
Dimension:
LSB
0 1 N/
А
Sets the output pressure
depending on the value
written:
0: close to the minimum
setpoint
1: close to the zero setpoint
2: close to the maximum
setpoint
Authorization
start
ADDR: 0x10C8
Holding
register
Dimension:
9999
0 1 N/A
Starts authentication
procedure for Manufactoring
mode
Key write
ADDR: 0x10C9
Holding
register
Dimension:
LSB
0 1 N/A
Writes the generated key
from the seed
Config ongoing
ADDR: 0x10CA
Holding
register
Dimension:
9999
0 1 N/A
Keeps the manufacturing
mode ongoing